PKW, HYUNDAI, General, IONIQ PLUG-IN (AE PHEV), 2019, G 1.6 GDI PHEV, G 1.6 GDI PHEV - Motor Control System (MCU)
G 1.6 GDI PHEV - Motor Control System (MCU) - 0
Identifikation
SubSystem ECU Software Number :: --
Supplier ECU hardware number: --
Fehlercode
Controls
Fehlercode löschen
Ist-Werte
MCU service lamp on request flag: --
MCU fault flag: --
MCU ready flag: --
MCU warning flag: --
Drive motor controllable flag: --
Drive motor actuation test flag: --
Main relay cutoff request flag by MCU (Immediately): --
MCU MIL on request flag: --
Enable flag for electric water Pump(EWP) operation: --
Radiator fan On/Off request: --
Delayed relay cut-off request by MCU: --
MCU anti-jerk activation flag: --
Delayed relay cut-off request by MCU(GCU): --
Engine speed limit flag by MCU: --
The flag for resolver calibration: --
Engine speed limit flag by MCU(GCU): --
MCU(GCU) service lamp on request flag: --
MCU(GCU) fault flag: --
MCU(GCU) ready flag: --
MCU(GCU) warning flag: --
Generator(HSG) controllable flag: --
Generator(HSG) actuation test flag: --
Main relay cutoff request flag by MCU (GCU) (Immediately): --
MCU(GCU) MIL on request flag: --
Inverter DC link voltage: -- V
Auxiliary battery voltage: -- V
Electric water Pump(EWP) operation status: --
Electric water Pump(EWP) speed: -- UpM
AVN down switch: -- V
Zündspannung: -- V
Actual driver motor speed: -- UpM
Drive motor torque reference: -- N·m
Actual driver motor torque: -- N·m
Drive motor phase current (RMS value): -- Arms
Temperatur Fahrmotor: -- °C
MCU temperature: -- °C
Drive motor U phase current sensor offset: --
Drive motor V phase current sensor offset: --
Drive motor resolver offset: -- rad
Drive motor resolver CAL command: --
Drive motor resolver mal counter: --
MCU gate board fault counter: --
Motor resolver lissajous mag: -- V
Motor resolver calibration permit code: --
Motor resolver position error compensation permitCode: --
Motor resolver position error 1st (Mag): --
Motor resolver position error 1st (Phase): -- rad
Motor resolver position error 2nd (Mag): --
Motor resolver position error 2nd (Phase): -- rad
Motor interlock flt counter: --
Motor unintended PWM OFF max time: --
HSG unintended PWM OFF max time: --
MCU over current flt counter: --
MCU A phase armshort counter: --
MCU B phase armshort counter: --
MCU C phase armshort counter: --
MCU SMPS flt counter: --
Heat sink temperature: -- °C
Actual generator (HSG) speed: -- UpM
Generator(HSG) torque reference: -- N·m
Actual generator (HSG) torque: -- N·m
Generator(HSG) phase current (RMS value): -- Arms
Generator(HSG) temperature: -- °C
MCU(GCU) temperature: -- °C
Generator(HSG) V phase current sensor offset: --
Generator(HSG) W phase current sensor offset: --
Generator(HSG) resolver offset: -- rad
Generator(HSG) resolver CAL command: --
Generator(HSG) resolver mal counter: --
MCU(GCU) gate board fault counter: --
HSG resolver lissajou mag: -- V
HSG resolver calibration permit code: --
HSG resolver position err comp permit code: --
HSG resolver position err 1 st (Mag): --
HSG resolver position err 1 st (Phase): -- rad
HSG resolver position err 2 nd (Mag): --
HSG resolver position err 2 nd (Phase): -- rad
HSG back emf temperature comp permit code: --
HSG back emf temperature comp value: --
DCLink offset compensation scale: --
DCLink offset compensation offset: --
DCLink offset compensation offset permitCode: --
GCU over current flt counter: --
GCU A phase armshort counter: --
GCU B phase armshort counter: --
GCU C phase armshort counter: --
GCU SMPS flt counter: --
Motor U phase armshort max count: -- Count
HSG U phase armshort max count: -- Count
Motor V phase armshort max count: -- Count
HSG V phase armshort max count: -- Count
Motor W phase armshort max count: -- Count
HSG W phase armshort max count: -- Count
Motor overcurrent max count: -- Count
HSG overcurrent max count: -- Count
Overvoltage max count: -- Count
Motor armshort DC count: -- Count
HSG armshort DC count: -- Count
Motor overcurrent DC count: -- Count
HSG overcurrent DC count: -- Count
Motor U phase POS value: --
Motor V phase POS value: --
Motor W phase POS value: --
HSG U phase POS value: --
HSG V phase POS value: --
HSG W phase POS value: --
Motor U phase NEG value: --
Motor V phase NEG value: --
Motor W phase NEG value: --
HSG U phase NEG value: --
HSG V phase NEG value: --
HSG W phase NEG value: --
Motor U phase cable open count: -- Count
HSG U phase cable open count: -- Count
Motor V phase cable open count: -- Count
HSG V phase cable open count: -- Count
Motor W phase cable open count: -- Count
HSG W phase cable open count: -- Count
Motor DQ control error max time: -- ms
HSG DQ control error max time: -- ms
Motor Id control error max value: --
HSG Id control error max value: --
Motor Iq control error max value: --
HSG Iq control error max value: --
Motor A phase current sensor offset min value: --
Motor B phase current sensor offset min value: --
HSG A phase current sensor offset min value: --
HSG B phase current sensor offset min value: --
Motor A phase current sensor offset max value: --
Motor B phase current sensor offset max value: --
HSG A phase current sensor offset max value: --
HSG B phase current sensor offset max value: --
Motor unintended PWM ON max time: -- ms
HSG unintended PWM ON max time: -- ms
Micom reset reason: --
Micom trap reason: --
Motor A phase current sensor high max time: -- ms
Motor B phase current sensor high max time: -- ms
HSG A phase current sensor high max time: -- ms
HSG B phase current sensor high max time: -- ms
Motor A phase current sensor low max time: -- ms
Motor B phase current sensor low max time: -- ms
HSG A phase current sensor low max time: -- ms
HSG B phase current sensor low max time: -- ms
Motor A phase current sensor high net time: -- ms
Motor B phase current sensor high net time: -- ms
HSG A phase current sensor high net time: -- ms
HSG B phase current sensor high net time: -- ms
Motor A phase current sensor low net time: -- ms
Motor B phase current sensor low net time: -- ms
HSG A phase current sensor low net time: -- ms
HSG B phase current sensor low net time: -- ms
Drive motor resolver cosine voltage: -- V
Drive motor resolver sine voltage: -- V
HSG resolver cosine voltage: -- V
HSG resolver sine voltage: -- V
Auxiliary battery voltage low fault net count: -- Count
Auxiliary battery voltage low warning net count: -- Count
Auxiliary battery voltage high fault net count: -- Count
Auxiliary battery voltage high warning net count: -- Count
Auxiliary battery voltage max value: -- V
Auxiliary battery voltage min value: -- V
DC link voltage high warning net count: -- Count
DC link voltage low fault net count: -- Count
DC link voltage low warning net count: -- Count
Maximal DC-link voltage: -- V
Minimum DC-link voltage: -- V
Motor speed max value: -- UpM
HSG speed max value: -- UpM
Motor speed warning net count: -- Count
HSG speed warning net count: -- Count
Motor unintended PWM OFF(A) net time: -- ms
HSG unintended PWM OFF(A) net time: -- ms
Motor unintended PWM OFF(B) net time: -- ms
HSG unintended PWM OFF(B) net time: -- ms
Motor unintended PWM OFF net count: -- Count
HSG unintended PWM OFF net count: -- Count
Motor inverter tmp sens noisy sig net count: -- Count
HSG inverter tmp sens noisy sig net count: -- Count
Motor inverter temperature sensor high net time: -- ms
HSG inverter temperature sensor high net time: -- ms
Motor inverter temperature sensor low net time: -- ms
HSG inverter temperature sensor low net time: -- ms
Motor tmp sens noisy sig net count: -- Count
HSG tmp sens noisy sig net count: -- Count
Motor temperature sensor high net time: -- ms
HSG temperature sensor high net time: -- ms
Motor temperature sensor low net time: -- ms
HSG temperature sensor low net time: -- ms
Heatsink temperature sensor noisy sig net time: -- ms
Heatsink temperature sensor high net time: -- ms
Heatsink temperature sensor low net time: -- ms
Motor IGBT over temperature net time: -- ms
HSG IGBT over temperature net time: -- ms
Motor inverter Jnction temperature max value: -- °C
HSG inverter Jnction temperature max value: -- °C
Motor inverter over temperature fault net time: -- ms
HSG inverter over temperature fault net time: -- ms
Motor inverter over temperature warning1 net time: -- ms
HSG inverter over temperature warning1 net time: -- ms
Motor inverter over temperature warning2 net time: -- ms
HSG inverter over temperature warning2 net time: -- ms
Motor inverter temperature max value: -- °C
HSG inverter temperature max value: -- °C
Motor inverter over temperature derating factor min value: -- %
HSG inverter over temperature derating factor min value: -- %
Motor over temperature fault net time: -- ms
HSG over temperature fault net time: -- ms
Motor over temperature warning1 net time: -- ms
HSG over temperature warning1 net time: -- ms
Motor over temperature warning2 net time: -- ms
HSG over temperature warning2 net time: -- ms
Motor temperature max value: -- °C
HSG temperature max value: -- °C
Heatsink temperature max value: -- °C
Motor resolver offset normal entry net count: -- Count
HSG resolver offset normal entry net count: -- Count
Motor resolver offset abnormal entry net count: -- Count
HSG resolver offset abnormal entry net count: -- Count
Motor interlock fault net time while driving: -- ms
HSG interlock fault net time while driving: -- ms
Motor interlock fault net time while not driving: -- ms
HSG interlock fault net time while not driving: -- ms
EWP (Electric Water Pump) abnormal performance net time: -- ms
EWP (Electric Water Pump) abnormal performance net count: -- Count
CAN1 BUS OFF net time: -- ms
CAN2 BUS OFF net time: -- ms
HCU CAN1 timeout net time: -- ms
HCU CAN2 timeout net time: -- ms
BMS CAN1 timeout net time: -- ms
BMS CAN2 timeout net time: -- ms
EWP CAN1 timeout net time: -- ms
TCU CAN1 timeout net time: -- ms
TCU CAN2 timeout net time: -- ms
EMS CAN1 timeout net time: -- ms
EMS CAN2 timeout net time: -- ms
iBAU(Integrated Brake Actuation Unit) CAN1 timeout net time: -- ms
CAN1 limp-home control net time: -- ms
CAN2 limp-home control net time: -- ms
Motor rsv dev fault net time: -- ms
HSG rsv dev fault net time: -- ms
Motor rsv avg fault net time: -- ms
HSG rsv avg fault net time: -- ms
Motor rsv diff fault net time: -- ms
HSG rsv diff fault net time: -- ms
Motor rsv rat fault net time: -- ms
HSG rsv rat fault net time: -- ms
Motor rsv diff dev: --
HSG rsv diff dev: --
Motor rsv S1 dev: --
HSG rsv S1 dev: --
Motor rsv S2 dev: --
HSG rsv S2 dev: --
Motor rsv S3 dev: --
HSG rsv S3 dev: --
Motor rsv S4 dev: --
HSG rsv S4 dev: --
Motor rsv S3-S4 diff dev: --
HSG rsv S3-S4 diff dev: --
Motor rsv S1-S3 diff dev: --
HSG rsv S1-S3 diff dev: --
Motor rsv S1-S2 diff dev: --
HSG rsv S1-S2 diff dev: --
Motor rsv S2-S4 diff dev: --
HSG rsv S2-S4 diff dev: --
Malfunction count init odometer: -- km
Error code 1: --
Target 1: --
Kilometerzähler 1: -- km
Error code 2: --
Target 2: --
Kilometerzähler 2: -- km
Error code 3: --
Target 3: --
Kilometerzähler 3: -- km
Error code 4: --
Target 4: --
Odometer 4: -- km
Error code 5: --
Target 5: --
Odometer 5: -- km
Error code 6: --
Target 6: --
Odometer 6: -- km
Error code 7: --
Target 7: --
Odometer 7: -- km
Error code 8: --
Target 8: --
Odometer 8: -- km
Error code 9: --
Target 9: --
Odometer 9: -- km
Last index: --
Dienstprogramme
Controls
Motor/HSG Resolver Calibration
Electric Water Pump Control
HPCU (MCU/GCU) self-diagnosis function
HPCU (MCU,GCU) diagnosis parameter initialization