Легковой транспорт, HYUNDAI, General, IONIQ HYBRID (AE HEV), 2018, G 1.6 GDI HEV, G 1.6 GDI HEV - HEV Motor Control System (MCU)

G 1.6 GDI HEV - HEV Motor Control System (MCU) - 0

Идентифи­кация

Номер программного обеспечения ЭБУ подсистемы: --

Номер аппаратного обеспечения поставщика ЭБУ: --

Коды неисправно­стей

Controls

Стирание DTC

Поток данных

MCU service lamp on request flag: --

MCU fault flag: --

MCU ready flag: --

MCU warning flag: --

Drive motor controllable flag: --

Drive motor actuation test flag: --

Main relay cutoff request flag by MCU (Immediately): --

MCU MIL on request flag: --

Enable flag for electric water Pump(EWP) operation: --

Вентилятор радиатора - запрос вкл/выкл: --

Delayed relay cut-off request by MCU: --

MCU anti-jerk activation flag: --

Delayed relay cut-off request by MCU(GCU): --

Engine speed limit flag by MCU: --

The flag for resolver calibration: --

Engine speed limit flag by MCU(GCU): --

MCU(GCU) service lamp on request flag: --

MCU(GCU) fault flag: --

MCU(GCU) ready flag: --

MCU(GCU) warning flag: --

Generator(HSG) controllable flag: --

Generator(HSG) actuation test flag: --

Main relay cutoff request flag by MCU (GCU) (Immediately): --

MCU(GCU) MIL on request flag: --

Inverter DC link voltage: -- В

Auxiliary battery voltage: -- В

Рабочее состояние электрического водяного насоса (EWP): --

Скорость электрического водяного насоса (EWP): -- об/мин

AVN down switch: -- В

Напряжение зажигания: -- В

Actual driver motor speed: -- об/мин

Drive motor torque reference: -- Н·м

Actual driver motor torque: -- Н·м

Drive motor phase current (RMS value): -- Arms

Температура приводного электродвигателя: -- °C

MCU temperature: -- °C

Drive motor U phase current sensor offset: --

Drive motor V phase current sensor offset: --

Drive motor resolver offset: -- радиан

Drive motor resolver CAL command: --

Drive motor resolver mal counter: --

MCU gate board fault counter: --

Motor resolver lissajous mag: -- В

Motor resolver calibration permit code: --

Motor resolver position error compensation permitCode: --

Motor resolver position error 1st (Mag): --

Motor resolver position error 1st (Phase): -- радиан

Motor resolver position error 2nd (Mag): --

Motor resolver position error 2nd (Phase): -- радиан

Motor interlock flt counter: --

Motor unintended PWM OFF max time: --

HSG unintended PWM OFF max time: --

MCU over current flt counter: --

MCU A phase armshort counter: --

MCU B phase armshort counter: --

MCU C phase armshort counter: --

MCU SMPS flt counter: --

Heat sink temperature: -- °C

Actual generator (HSG) speed: -- об/мин

Generator(HSG) torque reference: -- Н·м

Actual generator (HSG) torque: -- Н·м

Generator(HSG) phase current (RMS value): -- Arms

Generator(HSG) temperature: -- °C

MCU(GCU) temperature: -- °C

Generator(HSG) V phase current sensor offset: --

Generator(HSG) W phase current sensor offset: --

Generator(HSG) resolver offset: -- радиан

Generator(HSG) resolver CAL command: --

Generator(HSG) resolver mal counter: --

MCU(GCU) gate board fault counter: --

HSG resolver lissajou mag: -- В

HSG resolver calibration permit code: --

HSG resolver position err comp permit code: --

HSG resolver position err 1 st (Mag): --

HSG resolver position err 1 st (Phase): -- радиан

HSG resolver position err 2 nd (Mag): --

HSG resolver position err 2 nd (Phase): -- радиан

HSG back emf temperature comp permit code: --

HSG back emf temperature comp value: --

DCLink offset compensation scale: --

DCLink offset compensation offset: --

DCLink offset compensation offset permitCode: --

GCU over current flt counter: --

GCU A phase armshort counter: --

GCU B phase armshort counter: --

GCU C phase armshort counter: --

GCU SMPS flt counter: --

Утилиты

Controls

Motor/HSG Resolver Calibration

Управление электрическим водяным насосом

HPCU (MCU/GCU) self-diagnosis function