Bil, HYUNDAI, General, IONIQ HYBRID (AE HEV), 2017, G 1.6 GDI HEV, G 1.6 GDI HEV - HEV Motor Control System (MCU)
G 1.6 GDI HEV - HEV Motor Control System (MCU) - 0
Identifikation
SubSystem ECU Software Number :: --
Supplier ECU hardware number: --
Fejlkoder
Controls
Clear DTC
Levende Data
MCU service lamp on request flag: --
MCU fault flag: --
MCU ready flag: --
MCU warning flag: --
Drive motor controllable flag: --
Drive motor actuation test flag: --
Main relay cutoff request flag by MCU (Immediately): --
MCU MIL on request flag: --
Enable flag for electric water Pump(EWP) operation: --
Radiator fan On/Off request: --
Delayed relay cut-off request by MCU: --
MCU anti-jerk activation flag: --
Delayed relay cut-off request by MCU(GCU): --
Engine speed limit flag by MCU: --
The flag for resolver calibration: --
Engine speed limit flag by MCU(GCU): --
MCU(GCU) service lamp on request flag: --
MCU(GCU) fault flag: --
MCU(GCU) ready flag: --
MCU(GCU) warning flag: --
Generator(HSG) controllable flag: --
Generator(HSG) actuation test flag: --
Main relay cutoff request flag by MCU (GCU) (Immediately): --
MCU(GCU) MIL on request flag: --
Inverter DC link voltage: -- V
Auxiliary battery voltage: -- V
Electric water Pump(EWP) operation status: --
Electric water Pump(EWP) speed: -- Omdr.
AVN down switch: -- V
Tændingsspænding: -- V
Actual driver motor speed: -- Omdr.
Drive motor torque reference: -- N·m
Actual driver motor torque: -- N·m
Drive motor phase current (RMS value): -- Arms
Temperatur for drivmotor: -- °C
MCU temperature: -- °C
Drive motor U phase current sensor offset: --
Drive motor V phase current sensor offset: --
Drive motor resolver offset: -- rad
Drive motor resolver CAL command: --
Drive motor resolver mal counter: --
MCU gate board fault counter: --
Motor resolver lissajous mag: -- V
Motor resolver calibration permit code: --
Motor resolver position error compensation permitCode: --
Motor resolver position error 1st (Mag): --
Motor resolver position error 1st (Phase): -- rad
Motor resolver position error 2nd (Mag): --
Motor resolver position error 2nd (Phase): -- rad
Motor interlock flt counter: --
Motor unintended PWM OFF max time: --
HSG unintended PWM OFF max time: --
MCU over current flt counter: --
MCU A phase armshort counter: --
MCU B phase armshort counter: --
MCU C phase armshort counter: --
MCU SMPS flt counter: --
Heat sink temperature: -- °C
Actual generator (HSG) speed: -- Omdr.
Generator(HSG) torque reference: -- N·m
Actual generator (HSG) torque: -- N·m
Generator(HSG) phase current (RMS value): -- Arms
Generator(HSG) temperature: -- °C
MCU(GCU) temperature: -- °C
Generator(HSG) V phase current sensor offset: --
Generator(HSG) W phase current sensor offset: --
Generator(HSG) resolver offset: -- rad
Generator(HSG) resolver CAL command: --
Generator(HSG) resolver mal counter: --
MCU(GCU) gate board fault counter: --
HSG resolver lissajou mag: -- V
HSG resolver calibration permit code: --
HSG resolver position err comp permit code: --
HSG resolver position err 1 st (Mag): --
HSG resolver position err 1 st (Phase): -- rad
HSG resolver position err 2 nd (Mag): --
HSG resolver position err 2 nd (Phase): -- rad
HSG back emf temperature comp permit code: --
HSG back emf temperature comp value: --
DCLink offset compensation scale: --
DCLink offset compensation offset: --
DCLink offset compensation offset permitCode: --
GCU over current flt counter: --
GCU A phase armshort counter: --
GCU B phase armshort counter: --
GCU C phase armshort counter: --
GCU SMPS flt counter: --
Muligheder
Controls
Motor/HSG Resolver Calibration
Electric Water Pump Control
HPCU (MCU/GCU) self-diagnosis function