PKW, HYUNDAI, General, IX35 FCEV (LM FCEV), 2014, 100KW, EV battery system (BMS)
Hochspannungs- batterie - EV battery system (BMS) - 0
Identifikation
Fahrzeug-Identifizierungsnummer:
Supplier ECU hardware number:
Programmierdatum: FF FF FF FF
ECU software version number:
Fehlercode
Controls
Fehlercode löschen
Ist-Werte
State of battery charge (BMS): 127.5 %
Available charge power: 65535 W
Available discharge power: 65535 W
BMS weld flag: Ja
BMS main relay ON status: Ja
BMS controllable state: Ja
BMS warning: Ja
BMS fault: Ja
Battery DC current: -0.1 A
Battery DC voltage: 6553.50 V
Battery max temperature: 255 °C
Battery min temperature: 255 °C
Battery module 1 temperature: 255 °C
Battery module 2 temperature: 255 °C
Battery module 3 temperature: 255 °C
Battery module 4 temperature: 255 °C
Battery inlet temperature: 255 °C
Max cell voltage: 5.100 V
Max cell voltage no.: 255
Min cell voltage: 5.100 V
Min cell voltage no.: 255
Fan status: 255
Fan feedback frequency: 255 Hz
Auxiliary battery voltage: 25.50 V
Accumulative charge current: 429496729.5 Ah
Accumulative discharge current: 429496729.5 Ah
Accumulative charge power: 429496729.5 kWh
Accumulative discharge power: 429496729.5 kWh
Accumulative operating time: 4294967295 sec
HDC ready: Ja
FCU ready: Ja
HDC run: Ja
FCU LDC run command: Ja
HDC relay off request: Ja
FCU emergency mode: Ja
FCU vehicle ready: Ja
Inverter capacitor voltage: 65535 V
Isolation resistance: 65535 kOhm
Battery cell voltage 1: 5.100 V
Battery cell voltage 2: 5.100 V
Battery cell voltage 3: 5.100 V
Battery cell voltage 4: 5.100 V
Battery cell voltage 5: 5.100 V
Battery cell voltage 6: 5.100 V
Battery cell voltage 7: 5.100 V
Battery cell voltage 8: 5.100 V
Battery cell voltage 9: 5.100 V
Battery cell voltage 10: 5.100 V
Battery cell voltage 11: 5.100 V
Battery cell voltage 12: 5.100 V
Battery cell voltage 13: 5.100 V
Battery cell voltage 14: 5.100 V
Battery cell voltage 15: 5.100 V
Battery cell voltage 16: 5.100 V
Battery cell voltage 17: 5.100 V
Battery cell voltage 18: 5.100 V
Battery cell voltage 19: 5.100 V
Battery cell voltage 20: 5.100 V
Battery cell voltage 21: 5.100 V
Battery cell voltage 22: 5.100 V
Battery cell voltage 23: 5.100 V
Battery cell voltage 24: 5.100 V
Battery cell voltage 25: 5.100 V
Battery cell voltage 26: 5.100 V
Battery cell voltage 27: 5.100 V
Battery cell voltage 28: 5.100 V
Battery cell voltage 29: 5.100 V
Battery cell voltage 30: 5.100 V
Battery cell voltage 31: 5.100 V
Battery cell voltage 32: 5.100 V
Battery cell voltage 33: 5.100 V
Battery cell voltage 34: 5.100 V
Battery cell voltage 35: 5.100 V
Battery cell voltage 36: 5.100 V
Battery cell voltage 37: 5.100 V
Battery cell voltage 38: 5.100 V
Battery cell voltage 39: 5.100 V
Battery cell voltage 40: 5.100 V
Battery cell voltage 41: 5.100 V
Battery cell voltage 42: 5.100 V
Battery cell voltage 43: 5.100 V
Battery cell voltage 44: 5.100 V
Battery cell voltage 45: 5.100 V
Battery cell voltage 46: 5.100 V
Battery cell voltage 47: 5.100 V
Battery cell voltage 48: 5.100 V
Battery cell voltage deviation: 5.100 V
Stellgliedtest
Controls
Fan 1st
Fan 2nd
Fan 3rd
Fan 4th
Fan 5th
Fan 6th
Fan 7th
Fan 8th
Fan 9th
Fan Stop
Main Relay(-) ON
Precharge Relay ON
Main Relay(-), Precharge Relay ON simultaneous
Main Relay(-), Main Relay(+) ON Normal Sequence