Bil, HYUNDAI, General, I20 (PB), 2015, D 1.4 TCI-U2, Smart key code saving (without ESCL) (SMK)

Keyless - Smart key code saving (without ESCL) (SMK) - 0

Identifikation

Vehicle name: €

Dele nummer:

Part name:

Fremstillings dato:

Softwareversion: FF FF

Product no. ::

Serie nummer: FF FF FF FF FF

Can DB Ver. :: FF FF

Hardware version nummer: FF

Fejlkoder

B1602: CAN-bus communication error

B1603: CAN-bus off

Controls

Clear DTC

Levende Data

Start stop button 2: Tænd

ACC: Tænd

Ignition 1: Tænd

Gearshift P Position(AT)/Clutch(MT): Tænd

Driver door handle toggle button switch: Tænd

Passenger door handle toggle button switch: Tænd

Stop light switch: Tænd

Start stop button 1: Tænd

Trunk lid switch (Tail gate switch): Tænd

Ignition 2: Tænd

Start relay feed back signal: Tænd

Stop lamp fuse status: Tænd

Battery voltage (ADC): 20.40 V

Motor Hastighed: 8160 Omdr.

Køretøjs hastighed : 255 km/h

ACC relay voltage output: 20.40 V

IGN1 relay voltage output: 20.40 V

IGN2 relay voltage output: 20.40 V

Starter relay voltage output: 20.40 V

Battery voltage monitoring Input(by Load): 20.40 V

Immobilizer telltale: Tænd

External buzzer: Tænd

Start stop button LED blue/green: Tænd

ACC relay output: Tænd

Start stop button illumination GND output: Tænd

Ignition 1 relay output: Tænd

Start stop button illumination power output: Tænd

Ignition 2 relay output: Tænd

Start stop button LED amber: Tænd

Starter relay output: Tænd

IGN1 OFF output: Tænd

IGN2 OFF output: Tænd

Ignition 1 output circuit short to battery: Tænd

ACC output short circuit to Battery(Present): Tænd

Ignition 1 output circuit short to ground: Tænd

ACC output circuit short to ground(Present): Tænd

IGN1 input short circuit to Battery(Present): Tænd

ACC input short circuit to Battery(Present): Tænd

IGN1 input Open(Present): Tænd

ACC input Open(Present): Tænd

Starter output short circuit to Battery(Present): Tænd

Ignition 2 output circuit short to battery: Tænd

Starter output circuit short to ground(Present): Tænd

Ignition 2 output circuit short to ground: Tænd

Starter P/N SW short circuit to Battery(Present): Tænd

IGN2 input short circuit to Battery(Present): Tænd

IGN2 input Open(Present): Tænd

Button status: --

Key n p1 is learnt: --

Key n p2 is learnt: --

Transponder status: --

SMK status: --

Number of learnt FOB key: 255

Udgangs test

Controls

Start stop button LED amber

Start stop button LED blue/green

Start Stop Button Illumination

ACC relay

IGN1 Relay

IGN2 Relay

Start Relay

External buzzer

Immobilizer telltale

Interior antenna 1

Interior antenna 2

Trunk antenna (Sedan only)

Bumper/tailgate antenna

Left Door Handle Antenna

Right Door Handle Antenna

Muligheder

Controls

Interior antenna 1

Interior antenna 2

Trunk antenna (Sedan only)

Bumper/tailgate antenna

Driver door handle antenna

Passenger door handle antenna

ECM neutralization

SMK neutralization

SMK status information

Fjernbetjenings nøgle status

Current FOB key check

Smart key code saving