Bil, DACIA, DUSTER, Transmission control module (BVA)

transakse - Transmission control module (BVA) - 0

Identifikation

Program number: 01 04

Softwareversion: 00 00

Kalibreringsnummer: 00 00

MPR reference: 82 00 13 89 52

Electronic version: 61 00 95 02 00

Diagnose version: 08

Supplier: 219

Stel nr.: VF1BG0W0A29195448

Transmission oil drain date:

Oil wear counter:

Read date of last after sales operation:

Fejlkoder

DF177 [DEF]: Transmission overheat - circuit high voltage

Controls

Clear DTC

Levende Data

ECU supply voltage: 0.0 V

Change down request: Inaktiv

Multifunction switch P/N: Aktiv

Multifunction switch S2: Aktiv

Multifunction switch S3: Aktiv

Multifunction switch S4: Inaktiv

Fault warning light control: Aktiv

Oil too hot information: Nej

Solenoid valve supply: Missing

Reduktion af drejningsmoment: Inaktiv

Exchanger flow control solenoid valve: Inaktiv

Lever locking electromagnet control: Inaktiv

Solenoid valve control sequence 1: Inaktiv

Solenoid valve control sequence 2: Inaktiv

Solenoid valve control sequence 3: Inaktiv

Solenoid valve control sequence 4: Inaktiv

Solenoid valve control sequence 5: Inaktiv

Solenoid valve control sequence 6: Inaktiv

Rough pedal position: -- %

Manual mode: --

Snow mode: --

Stop contact (close): --

Stop contact (open): --

Lever position: --

Beregnet motordrejningsmoment: -- N·m

Køretøjs hastighed : -- km/h

Torque converter: --

Turbine speed/Engine speed difference: -- Omdr.

Reference pressure: 0.0 bar

Oil pressure: 0.0 bar

Transmission oil temperature: -50 °C

Motor Hastighed: 0 Omdr.

Turbine speed: 0 Omdr.

Standard pedal position: 0.0 %

Gaspedalposition: 0 %

Motor kølevæske temperatur føler: -50 °C

Motordrejningsmoment: -100 N·m

Initial ratio: Frigear

Udgangs test

Controls

Actuators sequential control

Selector lever locking electromagnet

Solenoid valve control sequence 1

Solenoid valve control sequence 2

Solenoid valve control sequence 3

Solenoid valve control sequence 4

Solenoid valve control sequence 5

Solenoid valve control sequence 6

Modulation solenoid valve

Converter lock-up solenoid valve

Selector lever locking electromagnet

Heat exchanger output solenoid valve

Muligheder

Controls

V009 Write date of last after sales operation

V016 Write transmission oil change date

V001 Rediger stel nr.

V015 Note oil wear counter

R005 Auto-adaptives