Bil, CITROEN, C-ZERO, HVAC

Klima Anlæg - HVAC - 0

Identifikation

ECU ID: 00 01

Fejlkoder

B1015: Heater water temperature sensor - range/performance

Controls

Clear DTC

Levende Data

Motor kølevæske temperatur føler: -40.0 °C

Ambient temperature sensor: 9.4 °C

Air thermo sensor: -29.0 °C

Interior air temperature sensor: -35.8 °C

Front blower fan: 25.5 V

Distribution motor position: Ikke defineret

Evaporator icing up safety status: Aktiv

Air purge mode active flag: Sluk

Rear defogger relay: Ikke aktiv

In/out select damper switch (output): Fresh

A/C-kontakt: Ikke aktiv

Illumination: Ikke aktiv

Bagrudeafdugningskontakt: Ikke aktiv

Air distribution:

Ventilation control:

A/C setting temperature: Ikke defineret

In/out select damper switch (input): Ikke aktiv

Udgangs test

Controls

Rear defogger output

Fresh/recirculated air flap switch output

Blower fan output

Mode motor output

Temperature dial position output

Frost protection output

Air purge mode output