Bil, CITROEN, DS5, RHD - DCM3.5 BR2
RHD - DCM3.5 BR2 - 0
Identifikation
PSA reference: 96 66 91 25 80
ECU manufacturer: VDO
Additional number: 96 66 91 25 80
Softwareversion: 03 00
Software reference: 79 23 63
Fejlkoder
P2125: Air metering valve. Drift on the initialisations of one of the two stops
Controls
Clear DTC
Levende Data
Status limit vehicle speed: Ikke aktiveret
Condition of neutral sensor: SANDT
Clutch pedal: 0 %
Locking of the ECU: Ulåst
Statspærrestatus: Matched ECU
Problem detected when transmitting the unlock code: No problem
Motor status: Motor kører
Camshaft and crankshaft synchronization: Ja
Mixer programming status: Done
EGR valve learning status: Done
Turbo learning: Not carried out
First initialisation of the air mixer: Done
Status of first learning of EGR valve: Done
First initialisation of the turbo: Done
EGR valve high limit initial programming: 88 %
Last initialised position of EGR valve lower limit: 12 %
EGR valve high limit last programming: 87 %
EGR valve low limit last programming: 13 %
Initialised initial position of the air mixer upper limit: 87 %
Initialised initial position of the air mixer lower limit: 14 %
Last initialised position of the air mixer upper limit: 87 %
Last initialised position of the air mixer lower limit: 13 %
Initialised initial position of the turbo upper limit: 69 %
Initialised initial position of the turbo lower limit: 27 %
Last initialised position of turbo upper limit: 59 %
Last initialised position of turbo lower limit: 20 %
Motor Hastighed: 0 Omdr.
Køretøjets hastighed sensor: 0 km/h
Gaspedalposition: 0 %
Fuel flow regulator: 0 %
Target fuel pressure: 0 bar
Fuel pressure measured: 0 bar
Injected flow measured: 0.0 mg/impulse
Brændstoftemperaturføler: -50 °C
Injector opening correction strategies activation status: Inaktiv
Injection time cylinder 1: 0.0 ms
Injection time cylinder 3: 0.0 ms
Injection time cylinder 4: 0.0 ms
Injection time cylinder 2: 0.0 ms
Fuel flow regulator: 0.0 mA
Air flow sensor air temperature: 10 °C
Inlet air temperature at manifold: 15 °C
Turbocharging pressure reference value: 65360 mbar
Measured turbo pressure: 65070 mbar
Barometrisk tryk føler: 65483 mbar
Turbo position setting: 237 %
Turbo position repeat: 230 %
Mixer position reference value: 245 %
Mixer position repeat: 229 %
Status for fartpilotsystem: Inaktiv
Clutch pedal: Nedtrykket
Hastighedsbegrænser: Inaktiv
Principal brake pedal: Udløst
Brake pedal redundant: Udløst
Accelerator pedal point of resistance sensor: Not exceeded
Speeder pedal positions føler N1: 257 mV
Speeder pedal position N2: 257 mV
Gear transmission ratio: 1
Gearbox type: Manuelt
Cruise control speed setting: 1 km/h
Speed limiter speed setting: 1 km/h
Generator progressive charge reference: 1 %
Batteri spænding: 0.10 V
Supply voltage 5V N1: 257 mV
Power relay: Aktiv
Starter control: No piloting of starter motor
Additional heating: Aktiv
Motor kølevæske temperatur føler: -50 °C
Cooling fan reference speed: 13 %
Køleventilatorhastighed: 10 %
Fan speed 2 setting: Low speed engaged
A/C circuit pressure: 1.0 bar
Oil pressure: Utilstrækkeligt
Oil level: 10 mV
Cylinder 1 injector code: 74RMWT8MA9CUE7KU5TX4
Cylinder 2 injector code: L4RMLXS4612PCLJAMNUA
Cylinder 3 injector code: F4YY0TB3TDJXHR5KMYYY
Cylinder 4 injector code: X4WT0US2TDAUG7KK5YZ9
DPF information
Motor Hastighed: 0 Omdr.
Air flow sensor air temperature: 10 °C
Inlet air temperature at manifold: 15 °C
Mixture calculated by the O2 sensor: 0.010
Activation heating O2 sensor: 10 %
Diesel Particulate filter (DPF) soot mass: 35.3 g/l
Diesel Particulate filter (DPF) cinder count: 10 %
Diesel Particulate filter (DPF) distance before replacing: 46 km
Diesel Particulate filter (DPF) differential pressure: 65199 mbar
Additive tank: 10 ml
Volume of additive remaining in the reservoir: 23 ml
Quantity of additive deposited in the filter: 1 g
Diesel Particulate filter (DPF) temperature: 273 °C
Authorisation of regeneration: Nej
Additive minimum level: Not reached
Diesel Particulate filter (DPF) regeneration status: Inaktiv
Power consuming equipment activation request: Nej
Diesel Particulate filter (DPF) distance since last regeneration: 257 km
Average distance between the last 10 regenerations: 10 km
Short term regeneration capacity: 15 %
Long term regeneration capacity: 10 %
Batteri spænding: 0.10 V
Udgangs test
Controls
High pressure fuel circuit leakage
Air mixer
Turbocharger actuator
EGR exchanger bypass
Checking pressurisation of air entering the engine
Manifold inlet pressure sensor checking
Checking engine setting
Air flow circulation
EGR circuit checking
Checking the functioning of the air circuit assembly
Cooling fan high speed
Cooling fan low speed
Indsprøjtnings dyse 1
Indsprøjtnings dyse 2
Indsprøjtnings dyse 3
Indsprøjtnings dyse 4
Fuel flow regulator
EGR-ventil
O2 sensor heating
Power supply relay
Pre-post heating relay control
Additional heater
Additive pump
Exhaust heat recovery valve checking
Muligheder
Controls
EGR valve change
EGR exchanger replacement
Turbocharger replacement
Mass air flow sensor replacement
Differential pressure sensor replacement
High Pressure pump replacement
Flow regulation valve replacement
Fuel rail pressure sensor replacement
Replacement of the diesel additive reservoir, of the pump or of the pipes
DPF replacement
Filling of the additive reservoir or pouch
Air mixer change
O2 sensor replacement
Change of engine ECU without the MAF
Change of engine ECU with the MAF
Ancillary drive belt replacement
Exhaust manifold replacement
Cylinder head replacement
DPF regeneration (vehicle stationary)
Injectors programming reinitialization
Injectors replacement