PKW, CITROEN, C-Crosser, Climate control
Klimaregelung - Climate control - 0
Identifikation
ECU origin: Mitsubishi
Hardwarenummer: 00 01
ECU reference: 7820A425
Diagnoseversion: 01 54
Softwareversion: 37 31 4B
Softwareversion:
FIN (ursprünglich): VF7VV4HNHAZ902746
Motortyp: 4HN
FIN: VF3VVSFZF9U903237
Fehlercode
U0184: Lost communication with audio module
Controls
Fehlercode löschen
Ist-Werte
Passenger compartment air temperature: 28.2 °C
Air thermo sensor: 30.2 °C
Driver photo sensor: 11.0 W/m2
Geber für Kühlmitteltemperatur: 34 °C
Außenlufttemperatur : 43.0 °C
Motordrehzahl: 0 UpM
Geber für Fahrgeschwindigkeit: 0.0 km/h
Driver air mix flap potentiometer: 100.0 %
Distribution motor position: 60.3 %
Front blower fan: 255
Target front blower fan: 255
Air outlet c/o potentiometer (target): Foot
In/out select damp poten (target): Fresh
Relais für Klimakompressor: AUS
Schalter für Klimaanlage: AUS
Schalter Heckscheibenheizung: AUS
Kondensator-Gebläse: 0 %
PTC heater 1: AUS
PTC heater 2: AUS
PTC heater 3: AUS
A/C setting temperature: 22.1 °C
A/C high pressure sensor: Normal
Niederdruck: Normal
Air outlet c/o set dial position: AUTO
A/C switch operation flag: AUS
Lüfter-: AUS
Lüfter+: AUS
Rear defogger switch lamp: AUS
Auto button telltale: Inaktiv
A/C request telltale: AUS
Defogger telltale: AUS
Air recirculation telltale: AUS
A/C compressor drive flag: AUS
Wiper operation flag: AUS
Batteriespannung: 12.10 V
IOD fuse eqipment flag: Richtig
Klimaanlage : Typ 4
System operation time: 10064860 sec
Compressor use times: 345706
Rear defogger use times: 1065
PTC heater 1 use times: 11123
PTC heater 2 use times: 6357
PTC heater 3 use times: 8415
In/out air c/o poten drive time: 226744.1 sec
Luftumwälzung: 46596.0 sec
Air mix flap potentiometer drive time: 287165.5 sec
Hot state time (interior temperature): 97 min
Cold state time (interior temperature): 56832 min
Hot state time (ambient temperature): 0 min
Cold state time (ambient temperature): 795.0 min
Maximale Außentemperatur: 83.5 °C
Minimale Außentemperatur: 0.0 °C
Maximum engine coolant temperature: 104 °C
Engine high speed time: 0 sec
Höchstdrehzahl: 4611 UpM
High pressure drive time: 0 min
High pressure cut-off times: 0
Höchstdruck: 164 kPa
A/C use rate: 9609705 sec
Compressor operation rate: 1768895 sec
Eco operation rate: 4446640 sec
Recirculation use rate: 2065 min
Face mode use rate: 3146 min
B/L mode use rate: 1113 min
Def mode use rate: 3564 min
Fan off use rate: 21165 sec
Fan 1-2 step use rate: 137380 sec
Fan 3-4 step use rate: 56135 sec
Fan 5-6 step use rate: 36095 sec
Fan 7-8 step use rate: 40000 sec
Temp 1-7 step use rate: 455 min
Temp 8-10 step use rate: 4915 min
Temp 11-13 step use rate: 60120 min
Temp 17-19 step use rate: 7565 min
Temp 20-22 step use rate: 485 min
Temp 23-29 step use rate: 295 min
Blower dial operation times: 1669
Stellgliedtest
Controls
In/out select damper
Air mix flap motor
Front blower fan
Air outlet c/o damper
Kondensator-Gebläse
Schalter für Klimaanlage
Rear defroster
PTC heater