Car, CADILLAC, SRX, 2014, HVAC
Climate control - HVAC - 0
Identification
VIN no: W0LGT8EBXA1007787
Programming date: 8209
Identifier: 00 00
Software module 1 identifier: 12654173
Software module 2 identifier: 55577673
Software module 3 identifier: 55577209
End model part number: 55577619
Base model part number: 55574337
DTC
Controls
Clear DTC
Data stream
Ambient air temperature (filtered): -40 °C
Engine coolant temperature: -40 °C
A/C high side pressure sensor: 0 kPa
A/C evaporator temperature sensor low resolution: -40 °C
Passenger compartment air temperature (unfiltered): -40 °C
Passenger compartment air temperature (filtered): -40 °C
Upper left duct air temperature sensor: -40 °C
Lower left duct air temperature sensor: -40 °C
Upper right duct air temperature sensor: -40 °C
Lower right duct air temperature sensor: -40 °C
Passenger compartment humidity: 0 %
Air quality sensor: 0 %
Sunload: 0 W/m²
Passenger compartment humidity sensor temperature: 0 °C
Windshield temperature: 0 °C
A/C evaporator temperature sensor high resolution: 0 °C
Battery voltage: 3.0 V
Blower motor speed: 0 %
Blower motor switch: Undefined
A/C request: No
Blower motor speed command: 0 %
Ignition voltage: 0.00 V
Rear defogger: Off
HVAC actuators supply voltage: Inactive
Mode switch: --
Auto recirculation indicator: Off
Enhanced defrost indicator: --
A/C telltale: --
Rear window defogger telltale: --
Air recirculation telltale: --
Auto HVAC indicator: --
Mode door actuator direction: Stop
Recirculation air flap motor diagnostic: direction of rotation: Stop
Left temperature door actuator direction: Stop
Air inlet door position: 0 Counts
Air inlet door actuator command: 0 Counts
Air inlet door actuator direction: Stop
Mode door position: 0 Counts
Mode door actuator command: 0 Counts
Air recirculation flap position: 0 Counts
Air recirculation flap command: 0 Counts
Left temperature door position: 0 Counts
Desired left temperature door actuator position: 0 Counts
Right temperature door actuator direction: Stop
Right temperature door position: 0 Counts
Desired right temperature door actuator position: 0 Counts
Auxiliary blower motor switch: Invalid
Auxiliary mode switch position: Invalid
Rear temperature door actuator learn status: Not run
Rear mode door actuator learn status: Not run
Auxiliary blower motor speed: 0 %
Upper rear duct temperature: -40 °C
Lower rear duct temperature: -40 °C
Auxiliary blower motor speed command: 0 %
Rear temperature door actuator direction: Stop
Rear mode door actuator direction: Stop
Rear mode door actuator position: 0 Counts
Desired rear mode door actuator position: 0 Counts
Rear temperature door actuator position: 0 Counts
Desired rear temperature door actuator position: 0 Counts
A/C compressor clutch inhibit Reason: Allowed
A/C compressor clutch: Disengaged
A/C compressor refrigerant solenoid valve command: 0 %
Auto recirculation switch: --
Enhanced defrost switch: --
MULTI-ZONE switch: --
Right temperature switch: --
Left temperature switch: --
A/C switch: --
Rear defogger switch: --
Air recirculation mode switch: --
Auto HVAC button: --
MULTI-ZONE indicator: Off
Security data
Security code lockout active timer: 0
Security code programming counter: 0
Security code reset counter: 0
Security code accepted: No
Security code programmed: No
Security code lockout: Inactive
Actuators test
Controls
Fresh air flap actuator
Air recirculation flap actuator
All Telltales test
A/C compressor solenoid valve
A/C switch
Auxiliary blower motor speed
Blower motor speed
Rear defogger
Mode door position
Rear mode door actuator position
Left temperature door actuator direction
Rear temperature door actuator direction
Right temperature door actuator direction
Utility
Controls
HVAC actuators learn
HVAC afterblow configuration