Car, CADILLAC, SRX, 2014, HVAC

Climate control - HVAC - 0

Identification

VIN no: W0LGT8EBXA1007787

Programming date: 8209

Identifier: 00 00

Software module 1 identifier: 12654173

Software module 2 identifier: 55577673

Software module 3 identifier: 55577209

End model part number: 55577619

Base model part number: 55574337

DTC

Controls

Clear DTC

Data stream

Ambient air temperature (filtered): -40 °C

Engine coolant temperature: -40 °C

A/C high side pressure sensor: 0 kPa

A/C evaporator temperature sensor low resolution: -40 °C

Passenger compartment air temperature (unfiltered): -40 °C

Passenger compartment air temperature (filtered): -40 °C

Upper left duct air temperature sensor: -40 °C

Lower left duct air temperature sensor: -40 °C

Upper right duct air temperature sensor: -40 °C

Lower right duct air temperature sensor: -40 °C

Passenger compartment humidity: 0 %

Air quality sensor: 0 %

Sunload: 0 W/m²

Passenger compartment humidity sensor temperature: 0 °C

Windshield temperature: 0 °C

A/C evaporator temperature sensor high resolution: 0 °C

Battery voltage: 3.0 V

Blower motor speed: 0 %

Blower motor switch: Undefined

A/C request: No

Blower motor speed command: 0 %

Ignition voltage: 0.00 V

Rear defogger: Off

HVAC actuators supply voltage: Inactive

Mode switch: --

Auto recirculation indicator: Off

Enhanced defrost indicator: --

A/C telltale: --

Rear window defogger telltale: --

Air recirculation telltale: --

Auto HVAC indicator: --

Mode door actuator direction: Stop

Recirculation air flap motor diagnostic: direction of rotation: Stop

Left temperature door actuator direction: Stop

Air inlet door position: 0 Counts

Air inlet door actuator command: 0 Counts

Air inlet door actuator direction: Stop

Mode door position: 0 Counts

Mode door actuator command: 0 Counts

Air recirculation flap position: 0 Counts

Air recirculation flap command: 0 Counts

Left temperature door position: 0 Counts

Desired left temperature door actuator position: 0 Counts

Right temperature door actuator direction: Stop

Right temperature door position: 0 Counts

Desired right temperature door actuator position: 0 Counts

Auxiliary blower motor switch: Invalid

Auxiliary mode switch position: Invalid

Rear temperature door actuator learn status: Not run

Rear mode door actuator learn status: Not run

Auxiliary blower motor speed: 0 %

Upper rear duct temperature: -40 °C

Lower rear duct temperature: -40 °C

Auxiliary blower motor speed command: 0 %

Rear temperature door actuator direction: Stop

Rear mode door actuator direction: Stop

Rear mode door actuator position: 0 Counts

Desired rear mode door actuator position: 0 Counts

Rear temperature door actuator position: 0 Counts

Desired rear temperature door actuator position: 0 Counts

A/C compressor clutch inhibit Reason: Allowed

A/C compressor clutch: Disengaged

A/C compressor refrigerant solenoid valve command: 0 %

Auto recirculation switch: --

Enhanced defrost switch: --

MULTI-ZONE switch: --

Right temperature switch: --

Left temperature switch: --

A/C switch: --

Rear defogger switch: --

Air recirculation mode switch: --

Auto HVAC button: --

MULTI-ZONE indicator: Off

Security data

Security code lockout active timer: 0

Security code programming counter: 0

Security code reset counter: 0

Security code accepted: No

Security code programmed: No

Security code lockout: Inactive

Actuators test

Controls

Fresh air flap actuator

Air recirculation flap actuator

All Telltales test

A/C compressor solenoid valve

A/C switch

Auxiliary blower motor speed

Blower motor speed

Rear defogger

Mode door position

Rear mode door actuator position

Left temperature door actuator direction

Rear temperature door actuator direction

Right temperature door actuator direction

Utility

Controls

HVAC actuators learn

HVAC afterblow configuration