Car, BMW, X1 (F49), Air conditioner (IHKA)
Climate control - Air conditioner (IHKA) - 0
Identification
Diagnostic version: 0F 11 90
Programming date: --
Supplier: Siemens
Manufacture date: 10.02.11
DTC
Controls
Clear DTC
Data stream
Left seat ventilation: --
Defrost: --
Right seat ventilation: --
Left air distribution: --
Right air distribution: --
Left outer ventilation flap: -- %
Right outer ventilation flap: -- %
Right middle ventilation flap: -- %
Left middle ventilation flap: -- %
Left rear mixiing flap: -- %
Right rear mixiing flap: -- %
Right front mixiing flap: -- %
Left front mixiing flap: -- %
Fresh air flap motor position: -- %
Left rear footwell vent flap: -- %
Right rear footwell vent flap: -- %
Left front footwell vent flap: -- %
Right front footwell vent flap: -- %
Air recirculation flap air flow to recirculating air: -- %
Defroster flap: -- %
Terminal R: --
Terminal 50: --
Terminal 30F: -- V
Terminal 15: --
Right ventilation temperature: -- °C
Left ventilation temperature: -- °C
Right heat exchanger temperature sensor: -- °C
Left heat exchanger temperature sensor: -- °C
Evaporator temperature sensor: -- °C
A/C compressor: --
Auxiliary heater: --
Fitting the pressure sensor: --
AUC sensor detection: --
Condensation sensor: --
Solar sensor control: --
Fitting the water valve: --
Fitting the dual water valve: --
Automatic rear conditioning system: --
Auxiliary water pump: --
A/C compressor clutch: --
Circulating pump: --
Electric water pump: --
Electric auxiliary air heater: --
Rear air conditioner: --
Running-in protection: -- sec
Running-in protection: --
Supply voltage (high-voltage electric system): -- V
Supply voltage (low-voltage electric system): -- V
DC/DC converter temperature: -- °C
EKK operating condition: --
EKK output limit: --
EKK reason for shutoff: --
EKK voltage range: --
Installation EKK: --
Electric auxiliary air heater: -- V
Electric auxiliary air heater: -- A
Electric auxiliary heater setpoint value: -- %
Calibration status: --
A/C button led: --
Automatic air recirculation control LED: --
Automatic function LED (one button): --
Automatic heating (AUC) LED: --
Defrost LED: --
Rear window heater button: --
LED, automatic function left: --
LED, automatic function right: --
MAX button LED: --
Actuators test
Controls
Display test
Activate running-in protection for A/C compressor
Deactivate running-in protection for A/C compressor
Blower at 80%
Right rear mixing flap at 100%
Right rear mixing flap at 0%
Left rear mixing flap at 100%
Left rear mixing flap at 0%
Rear right footwell flap at 100%
Right rear footwell flap at 0%
Left rear footwell flap at 100%
Left rear footwell flap at 0%
Fresh-air flap at 100%
Fresh-air flap at 0%
Right front mixing flap at 100%
Right front mixing flap at 0%
Left front mixing flap at 100%
Left front mixing flap at 0%
Right front footwell flap at 100%
Right front footwell flap at 0%
Left front footwell flap at 100%
Left front footwell flap at 0%
Right outer ventilation flap at 100%
Right outer ventilation flap at 0%
Right middle ventilation flap at 100%
Right middle ventilation flap at 0%
Left middle ventilation flap at 100%
Left middle ventilation flap at 0%
Left outer ventilation flap at 100%
Left outer ventilation flap at 0%
Recirculated-air flap at 100%
Recirculated-air flap at 0%
Defroster flap
Air distribution flap calibration
Addressing flap motors
Auxiliary heater unlocking