Car, PEUGEOT, iON, CMU_01

HV battery - CMU_01 - 0

Identification

ECU origin: Mitsubishi

Hardware number: 00 06

ECU reference: 9499A794

Diagnostic version: 00 10

Software version: 02 01 13

Software version: 8634A04904

VIN no (original): --

Motor type: --

VIN no: --

DTC

Controls

Clear DTC

Data stream

Module - voltage: 0.000 V

Cell total voltage: 0.000 V

Voltage diff. (Module-Total cell): 0.000 V

Cell A - voltage: 0.000 V

Cell B - voltage: 0.000 V

Cell C - voltage: 0.000 V

Cell D - voltage: 0.000 V

Cell E - voltage: 0.000 V

Cell F - voltage: 0.000 V

Cell G - voltage: 0.000 V

Cell H - voltage: 0.000 V

Cell monitor IC - Normal/Fail: Normal

Sensor - voltage: Normal

Reference low voltage: Normal

Reference high voltage: Normal

Temperature sensor 1 - open: Normal

Temperature sensor 2 - open: Normal

Temperature sensor 3 - open: Normal

Temperature sensor 4 - open: Normal

Temperature sensor 5 - open: Normal

Temperature sensor 6 - open: Normal

Temperature sensor 1 - short: Normal

Temperature sensor 2 - short: Normal

Temperature sensor 3 - short: Normal

Temperature sensor 4 - short: Normal

Temperature sensor 5 - short: Normal

Temperature sensor 6 - short: Normal

Cell A - voltage underflow: Normal

Cell B - voltage underflow: Normal

Cell C - voltage underflow: Normal

Cell D - voltage underflow: Normal

Cell E - voltage underflow: Normal

Cell F - voltage underflow: Normal

Cell G - voltage underflow: Normal

Cell H - voltage underflow: Normal

Cell B - voltage overflow: Normal

Cell A - voltage overflow: Normal

Cell C - voltage overflow: Normal

Cell D - voltage overflow: Normal

Cell E - voltage overflow: Normal

Cell F - voltage overflow: Normal

Cell G - voltage overflow: Normal

Cell H - voltage overflow: Normal

Temperature sensor 1 - underflow: Normal

Temperature sensor 2 - underflow: Normal

Temperature sensor 3 - underflow: Normal

Temperature sensor 4 - underflow: Normal

Temperature sensor 5 - underflow: Normal

Temperature sensor 6 - underflow: Normal

Temperature sensor 1 - overflow: Normal

Temperature sensor 2 - overflow: Normal

Temperature sensor 3 - overflow: Normal

Temperature sensor 4 - overflow: Normal

Temperature sensor 5 - overflow: Normal

Temperature sensor 6 - overflow: Normal

EEPROM fail (learning data read): Normal

CAN controller: Normal

Cell A - connection terminal: Normal

Cell C - connection terminal: Normal

Cell E - connection terminal: Normal

Cell G - connection terminal: Normal

A/D conversion (reference VOLT.): Normal

A/D conversion (temperature sensor 1): Normal

A/D conversion (temperature sensor 2): Normal

A/D conversion (temperature sensor 3): Normal

A/D conversion (temperature sensor 4): Normal

A/D conversion (temperature sensor 5): Normal

A/D conversion (temperature sensor 6): Normal

A/D conversion (module voltage): Normal