Bil, PEUGEOT, 2008, TDC RFTA MUX

Klima Anlæg - TDC RFTA MUX - 0

Identifikation

ECU manufacturer: Not available

Udstyrs nummer: 02 03 FF AE 00

Softwareversion: 03 05

Edition calibration: 01 02

Software reference: --

Dele nummer: 05 01 01 02

Stel nr.: VF34C5FWC55262609

Additional number: 05 06 07 08 09

Fejlkoder

U1802: Ukendt fejlkode

Controls

Clear DTC

Levende Data

Sunlight photo sensor: Ikke anvendt

Front condition evaporator sensor: Used

Evaporator temperature sensor: 23.1 °C

Sunlight photo sensor: 96.50 V

Passenger compartment air blower supply voltage: 5.30 V

Position of the air intake and recirculation motor: 185 %

Left front position mixing motor: 241 %

Right front position mixing motor: 95 %

Distribution motor position: 99 %

Ventilation reference value: 255 %

Driver temperature decrease request: Inaktiv

De-icing/visibility request: Inaktiv

Driver temperature increase request: Inaktiv

Recirculation request: Aktiv

Blower minus request: Inaktiv

Passenger temperature decrease request: Inaktiv

Blower plus request: Inaktiv

Passenger temperature increase request: Inaktiv

Auto: Inaktiv

A/C request: Inaktiv

Air distribution request : Inaktiv

Rear windscreen and door mirror de-icing request: Inaktiv

Levende Data

Sunlight photo sensor: Ikke anvendt

Front condition evaporator sensor: Used

Passenger compartment air blower supply voltage: 5.30 V

Position of the air intake and recirculation motor: 185 %

Ventilation reference value: 255 %

Recirculation request: Aktiv

Rear windscreen and door mirror de-icing request: Inaktiv

Levende Data

Sunlight photo sensor: Ikke anvendt

Front condition evaporator sensor: Used

Evaporator temperature sensor: 23.1 °C

Passenger compartment air blower supply voltage: 5.30 V

Position of the air intake and recirculation motor: 185 %

Ventilation reference value: 255 %

Recirculation request: Aktiv

A/C request: Inaktiv

Rear windscreen and door mirror de-icing request: Inaktiv

Udgangs test

Controls

Mixer motor

Left front mixing motor

Right front mixing motor

Air distribution motor