Car, PEUGEOT, 806, RHX - Bosch EDC15C2
RHX - Bosch EDC15C2 - 0
Identification
PSA reference: 96 36 32 16 80
ECU manufacturer: Valeo
Additional number: 96 46 02 35 80
Diagnostic version: 12
Calibration version: 02 01
Software version: 02 03
Emission: Not defined
ECU production date: --
Software reference: FF FF FF
DTC
P1402 [8]: Exhaust gas recirculation (EGR) throttle solenoid valve - circuit open or short to ground
Controls
Clear DTC
Data stream
Fuel temperature sensor: 56 °C
Supply voltage for sensors of group 1: 4.99 V
Supply voltage 2 for sensors: 4.99 V
Barometric pressure sensor: 0.965 bar
Cruise control switch: Inactive
Camshaft and crankshaft synchronization:
Measured turbo pressure: 0.988 bar
Target turbo pressure: 1.153 bar
Diesel pressure: 0.0706 A
Difference between fuel pressure measured and fuel pressure recommendation: 2.0 bar
Engine coolant temperature sensor: -30.0 °C
Air temperature sensor: 13.8 °C
Engine speed: 7774.4 rpm
Vehicle speed sensor: 255 km/h
Vehicle transmission type:
Gear transmission ratio:
Cooling fan low speed relay: Inactive
Cooling fan high speed relay: Inactive
Cooling fan circuit pressure: -- bar
Accelerator pedal position sensor: 0.0 %
Battery voltage: 12.35 V
Brake pedal switch 1: Inactive
Pre-post heating relay: Inactive
A/C cut-off request:
Fuel pressure sensor: 0.0 bar
Injected flow set point: 24.7 mm³/stk
Mass air flow sensor: 182.4 mg/impulse
Fuel njection advance (pre): 0.3 °
Fuel injection advance (main): 0.3 °
Injector voltage: 69.88 V
Injector 1 correction value: 0.0 mm³/stk
Injector 4 correction value: 0.0 mm³/stk
Injector 2 correction value: 0.0 mm³/stk
Injector 3 correction value: 0.0 mm³/stk
Diesel pressure: 4.7 %
3rd position deactivation:
Turbo pressure duty cycle: 14.9 °
EGR valve open cycle ratio: 4.7 %
EGR throttle electrovalve open cycle ratio: 5.5 %
DPF information
Locking of the ECU: Locked
Immobilizer status: Matched ECU
Problem detected when transmitting the unlock code: Engine immobiliser code cannot be read
Engine coolant temperature sensor: -30.0 °C
Air temperature sensor: 13.8 °C
Engine speed: 7774.4 rpm
Vehicle speed sensor: 10 km/h
Condition of the filter: Clogged particle filter
Regeneration assistance request: Inactive
Catalytic converter upstream temperature: 0.0 °C
Catalytic converter downstream temperature: 668.0 °C
Diesel Particulate filter (DPF) differential pressure: 0.0 mbar
Total additive quantity: 35 g
Activation of large power consumers: Yes
Air flow volume: 1640 m³/h
Bypass throttle solenoid valve open cycle ratio: 3.9 %
Post injection flow: 5.8 mm³/stk
Post injection phasing: -139 °
Engine coolant temperature sensor: 39.7 °C
Average distance between the last 5 regenerations: 700.0 km
Diesel Particulate filter (DPF) distance since last regeneration: 700.0 km
Actuators test
Controls
EGR throttle
Power supply relay
Diesel pressure regulation
EGR valve
Cooling fan high speed
Cooling fan low speed
Pre-post heating relay control
Coolant temperature telltale
Check engine telltale
3rd piston deactivation
Turbo pressure solenoid valve
Swirl flap solenoid
Preheating warning light
Fuel consumption signal
Utility
Controls
Diesel particulate filter static regeneration