Car, PEUGEOT, 508, RFTA MONOZONE

Climate control - RFTA MONOZONE - 0

Identification

ECU manufacturer: Valeo

Equipment number: 96 65 96 14 80

Software version: 07 00

Edition calibration: 04 00

Software reference: --

Part number: 00 33 23 52

VIN no: VF38D5FEACL008833

Additional number: 96 65 96 14 80

DTC

U1F0A: CAN fault

Controls

Clear DTC

Data stream

Right side condition of the sunlight sensor: --

Left side condition of the sunlight sensor: --

Front condition evaporator sensor: --

Passenger compartment air blower: --

Allocation of motor 1: --

Allocation of motor 2: --

Allocation of motor 3: --

Allocation of motor 4: --

Allocation of motor 5: --

Allocation of motor 6: --

Allocation of motor 7: --

Allocation of motor 8: --

Allocation of motor 9: --

Evaporator temperature sensor: 6550.0 °C

Driver side sunlight photo sensor: 96.5 %

Passenger side sunlight photo sensor: 119.5 %

Passenger compartment air blower supply voltage: 11.40 V

Position of the air intake and recirculation motor: 182 %

Left front position mixing motor: 240 %

Right front position mixing motor: 94 %

Left front distribution motor position : 88 %

Right front distribution motor position: 3 %

Data stream

Right side condition of the sunlight sensor: --

Left side condition of the sunlight sensor: --

Rear evaporator sensor: --

Right rear blown air sensor status: --

Front condition evaporator sensor: --

Left rear blown air sensor status: --

Air quality (concentration of nitrous monoxide NO) sensor: --

Air quality (concentration of carbon monoxide NO) sensor: --

Evaporator temperature sensor: 6550.0 °C

Driver side sunlight photo sensor: 96.5 %

Passenger side sunlight photo sensor: 119.5 %

Air quality sensor value (carbon monoxide: CO): 26.6 %

Air quality sensor value (nitrous oxide: NO): 0.6 %

Left rear blown air temperature: 6548.2 °C

Right rear blown air temperature: 6552.4 °C

Passenger compartment air blower supply voltage: 11.40 V

Position of the air intake and recirculation motor: 182 %

Left front position mixing motor: 240 %

Right front position mixing motor: 94 %

Left front distribution motor position : 88 %

Right front distribution motor position: 3 %

Left rear mixing motor position: 14 %

Right rear mixing motor position: 48 %

Left rear distribution motor position : 4 %

Right rear distribution motor position: 86 %

Data stream

Front condition evaporator sensor: --

Evaporator temperature sensor: 6550.0 °C

Passenger compartment air blower supply voltage: 11.40 V

Position of the air intake and recirculation motor: 182 %

Mixing motor position: 240 %

Distribution motor position: 88 %

Data stream

Front condition evaporator sensor: --

Evaporator temperature sensor: 6550.0 °C

Passenger compartment air blower supply voltage: 11.40 V

Position of the air intake and recirculation motor: 182 %

Actuators test

Controls

Mixer motor

Left front mixing motor

Right front mixing motor

Air distribution motor

Passenger compartment air blower

Distribution motor: ventilators