Car, MITSUBISHI, i-MiEV (HA0), 2017, HA4W, LDDL6, COMP&HTR COMP&HTR
Heater - COMP&HTR COMP&HTR - 0
Identification
Identifier: 00 06
ECU origin: 04
Supplier number: 65
ECU ID: 00
Diagnostic version: 06
Hardware version number: 00 01
Software version: 00 01 01
Part number: 7820A744
Software number: FFFFFF
VIN no (original): --
Class: --
Model: --
Type: --
Model year: --
VIN no: --
Calibration ID: --
Calibration verification number (CVN): --
DTC
B10C0: Interrior air temperature sensor - circuit shorted
U0184: Lost communication with audio module
Controls
Clear DTC
Data stream
Compressor speed: 32768 rpm
Compressor drive history flag: On
Climate power save active flag: Off
Cooling fan request (Climate): Off
Compressor inverter input power: 0 W
Refrigerant pressure sensor: 3.57 MPa
Electrical water heater test result: Not completed
Electrical water heater spec. judgment: Not completed
Electric water pump output: Off
Electrical water heater: 10200 W
Electrical water heater inlet sensor: 63.8 °C
Electrical water heater outlet sensor: -34.0 °C
Battery cooling request flag: Off
Pre A/C mode: SNA
Battery cooling control mode: Ventilation
Battery heating request flag: Off
Pre A/C control permit flag: Off
In/out select damper: Fresh
MAX switch control status: Off
A/C switch: Off
In/out select damper switch status: Fresh
MAX switch status: Off
Temperature control dial:
Air outlet c/o potentiometer: SNA
Blower fan output:
Interior temperature sensor: 16.0 °C
Ambient temperature sensor (Meter): 87.5 °C
Ambient temperature sensor (CAN Output): 47.5 °C
Air thermo sensor: 47.8 °C
Water temperature sensor (HVAC): 111.8 °C
Frost protection active flag: Off
Battery heating active flag: On
Air purge mode active flag: Off
Battery cooling active flag: Off
Pre A/C mode active flag: Off
Actuators test
Controls
Battery cooling flap motor
In/out select damper
Cooling fan (Climate)
Electic water heater test mode
Utility
Controls
Compressor drive history reset