Car, MITSUBISHI, PHEV (GG), 2020, GG3W, XDPHZL6, Air Conditioner

Climate control - Air Conditioner - 0

Identification

Identifier: 00 01

ECU origin: 04

Supplier number: 65

ECU ID: 00

Diagnostic version: 01

Hardware version number: 00 01

Software version: 00 01 01

Part number: 7820A744

Software number: FFFFFF

VIN no (original): JMBXTGF3WDZ003948

Class: TG

Model: Outlander / GF

Type: GF3W

Model year: 2014

VIN no: JMBXTGF3WEZ003948

Calibration ID: --

Calibration verification number (CVN): --

DTC

B1115: Electric water pump (EWP) malfunction

Controls

Clear DTC

Data stream

Interior temperature sensor: 18.0 °C

Air thermo sensor: 27.8 °C

Pressure sensor: 2.24 MPa

Photo sensor: 99.0 W/m2

Engine coolant temperature sensor: 82 °C

Ambient temperature sensor: 6.5 °C

Generator use rate: 0 %

Battery cooling air thermo sensor: 7.0 °C

Electrical water heater inlet sensor: 64.0 °C

Electrical water heater outlet sensor: 67.0 °C

Engine speed: 175 rpm

Vehicle speed: 77 km/h

Supply power for A/C: 5120 W

High voltage battery current: -325.72 A

High voltage battery voltage: 0.0 V

Driver air mix flap potentiometer: 7 %

Passenger air mix flap potentiometer: 5 %

Air outlet c/o potentiometer: 12 %

In/out select damp potentiometer: 0 %

Front blower fan: 0 steps

Target front blower fan: 0 steps

Air outlet c/o potentiometer (target): DEF

In/out select damp poten (target): Fresh

A/C compressor drive request: Off

Air conditioning switch: Off

Solenoid valve output: On

Rear defogger switch: Off

Condenser fan: 8 %

Engine start request: Off

Electrical water heater PTC1 output: Off

A/C inverter switch: Off

Electrical water heater PTC2 output: Off

Electrical water heater PTC3 output: Off

Compressor stop eternity: Off

Compressor over current: Off

Compressor drive status: Normal

Compressor controller fail: Off

Compressor sensor fail: Off

Compressor heat protection: Off

Compressor power fail: Off

Compressor voltage fail: Normal

Compressor drive flag (ignition cycle): Off

Compressor speed: 0 rpm

Compressor: 0 W

Electrical water heater level: 4 steps

Electrical water heater: 3200 W

Electric water pump: 100 %

High pressure fail flag: On

Low pressure fail flag: On

Refrigerant leak (Low pressure): In progress

Refrigerant leak (level 20%): Error

Driver seat setting temperature: 67.0 °C

Set temperature (Passenger side): 67.5 °C

Compressor drive history flag: Off

Battery cooling drive history flag: Off

Electrical water heater test result: Fail

ELC water pump drive his. flag: Off

Heated windshield test mode flag: Off

Heated windscreen equipment: Not present

ECO mode: ECO

Wiper operation flag: Off

Ignition/electric motor switch position information: On

Power source voltage: 14.5 V

IOD fuse eqipment flag: On

Crash down signal: Off

Pre air conditioning signal: Off

High voltage ready signal: On

Battery cooling request signal: Off

Shut down signal: On

Engine work time: 11950120 sec

System operation time: 201490 min

Ignition switch/Electric motor switch on time: 11983085 sec

Battery cooling time: 552935 sec

Compressor high speed drive time: 35370 sec

Solenoid valve operation counter: 3342 Count

Maximum pressure: 2.04 MPa

High pressure cut times: 0 Count

Compressor drive time: 2755230 sec

Compressor high pressure drive time: 0 sec

Electrical water heater PTC3 drive time: 1157770 sec

Electric water pump: 6528275 sec

High water temperature: 327675 sec

High water temperature cut counter: 0 Count

Maximum coolant temperature: 112 °C

Electrical water heater inlet max temperature: 101 °C

Electrical water heater outlet max temperature: 102 °C

Electrical water heater PTC1 drive time: 1722560 sec

Electrical water heater PTC2 drive time: 1614535 sec

Fan high driving time: 304260 sec

Fan lo driving time: 7581765 sec

Fan M1 driving time: 1298885 sec

Fan M2 driving time: 402325 sec

Actuators test

Controls

In/out select damper

Air outlet c/o damper

Condenser fan

A/C switch

Rear defogger switch

Electronic water heater test

Solenoid Valve Test

Engine start request

Electric water pump

Front blower fan

Driver air mix damper motor

As air mix damper motor

Utility

Controls

Compressor drive history reset

Battery cooling drive history reset

ELC water pump drive his. reset

Heated windscreen test mode

Heated windscreen test mode stop

Electronic water heater test