Car, MITSUBISHI, PHEV (GG), 2020, GG3W, XDPHZL6, Electric Heater

Heater - Electric Heater - 0

Identification

Identifier: 00 00

ECU origin: 04

Supplier number: 65

ECU ID: 00

Diagnostic version: 00

Hardware version number: 00 01

Software version: 00 01 01

Part number: 7820A744

Software number: FFFFFF

VIN no (original): --

Class: --

Model: --

Type: --

Model year: --

VIN no: --

Calibration ID: --

Calibration verification number (CVN): --

DTC

B10C0: Interrior air temperature sensor - circuit shorted

U0184: Lost communication with audio module

Controls

Clear DTC

Data stream

Heater power: 10200 W

Heater current: 0.0 A

Heater inlet temperature sensor: 215 °C

Heater outlet temperature sensor: -20 °C

Current fail at heater stop: Off

PTC heater 1: Off

Temperature sensor faulty: Off

PTC heater 2: Off

ECU internal voltage fail: Off

PTC heater 3: On

Heater power restriction: No restriction

PTC heater 4: Off

IGBT temperature fail: Off

Circuit board temperature fail: Off

Heater status: Normal

Short circuit (Overcurrent fail): Off

Heater circuit fail: Off

Input voltage fail (High voltage): Off

High water temperature fail: Off

Heater drive permission signal: On

Heater target water temperature: 128 °C

Heater power upper limit: 10200 W

Heater water temperature adjust value: 215 °C

Odometer: 420390.8 km

IGBT temperature sensor 1: -40 °C

IGBT temperature sensor 2: -40 °C

IGBT temperature sensor 3: -40 °C

IGBT temperature sensor 4: -40 °C

Circuit board temperature sensor: -40 °C

Input current (High voltage): 51.0 A

Input voltage (High voltage): 437.5 V

Electric heater test result: Normal

PTC heater 3 drive time: 196605 sec

PTC heater 4 drive time: 490 sec

System operation time: 8388608 min

PTC heater 1 drive time: 83886075 sec

PTC heater 2 drive time: 115 sec

PTC heater 4 use times: 12596 times

PTC heater 1 use times: 16777215 times

PTC heater 2 use times: 1619 times

PTC heater 3 use times: 1142 times

IGBT maximum temperature: 195 °C

Maximum current: 35.0 A

Maximum voltage: 305.0 V

Heater inlet maximum: 215 °C

Heater outlet maximum: 215 °C

Actuators test

Controls

PTC heater 1

PTC heater 2

PTC heater 3

PTC heater 4

Utility

Controls

Electric heater