Car, MERCEDES, C 206, 206.214 C 220 d 4MATIC All-Terrain Wagon, OM654 - MRD2 (CDI)
OM654 - MRD2 (CDI) - 0
Identification
Diagnostic version: 00 14 10
Boot software number: 0.0.0
Hardware version: 0.0.0
Software version: --
Software version 1: --
Software version 2: --
Supplier: --
Hardware part number:
Software part number (customer): --
Software part number (code): --
Software part number (data): --
Serial number: --
VIN stored:
DTC
P010000: Mass or volume air flow (MAF) sensor 1/A - electrical fault
Controls
Clear DTC
Data stream
Battery voltage: 0.00 V
Circuit 15: Off
Control module CDI activated: --
Start enable from EIS [EZS]: --
Test counter of drive authorization system: --
Input circuit 50: No
Input circuit 50: No
Engine speed: 0 rpm
Camshaft and crankshaft synchronization: Not synchronized
Fuel pump status: Not activated
Fuel high pressure sensor: 0 bar
Fuel level: 0 L
Pressure control solenoid valve: 0 mA
Fuel quantity control valve: 0 mA
Injection quantity: 0.00 mg/hub
Fuel pressure sensor: 0.00 bar
Boost pressure sensor: 0 hPa
Barometric pressure: 0 hPa
Fuel temperature sensor: -273 °C
Coolant temperature: 0 °C
Engine oil temperature sensor: 0 °C
Intake air temperature sensor: 0 °C
Accelerator pedal position sensor: 0 %
Correction factor injector cylinder 6: 0.0 mg/hub
Correction factor injector cylinder 5: 0.0 mg/hub
Correction factor injector cylinder 4: 0.0 mg/hub
Correction factor injector cylinder 3: 0.0 mg/hub
Correction factor injector cylinder 2: 0.0 mg/hub
Correction factor injector cylinder 1: 0.0 mg/hub
Fuel pump: 0 rpm
Fuel pump: 0.00 A
Fuel pump: 0 %
Oil pressure sensor: 0.0 bar
Rail pressure regulation status:
Total torque (after calculation): 0 N·m
Exhaust gas pressure: 0 hPa
Mass air flow sensor: 0.00 mg/hub
Adaptation value of cylinder 4 for calibration point 1600 bar: 0.00 us
Adaptation value of cylinder 2 for calibration point 1600 bar: 0.00 us
Adaptation value of cylinder 6 for calibration point 1600 bar: 0.00 us
Adaptation value of cylinder 3 for calibration point 1600 bar: 0.00 us
Adaptation value of cylinder 5 for calibration point 1600 bar: 0.00 us
Adaptation value of cylinder 1 for calibration point 1600 bar: 0.00 us
Current cylinder for calibration point 1600bar: 0
Current cylinder for calibration point 1200bar: 0
Current cylinder for calibration point 800bar: 0
Current cylinder for calibration point 300bar: 0
Adaptation value of cylinder 4 for calibration point 1200 bar: 0.00 us
Adaptation value of cylinder 2 for calibration point 1200 bar: 0.00 us
Adaptation value of cylinder 6 for calibration point 1200 bar: 0.00 us
Adaptation value of cylinder 3 for calibration point 1200 bar: 0.00 us
Adaptation value of cylinder 5 for calibration point 1200 bar: 0.00 us
Adaptation value of cylinder 1 for calibration point 1200 bar: 0.00 us
Adaptation value of cylinder 4 for calibration point 800 bar: 0.00 us
Adaptation value of cylinder 2 for calibration point 800 bar: 0.00 us
Adaptation value of cylinder 6 for calibration point 800 bar: 0.00 us
Adaptation value of cylinder 3 for calibration point 800 bar: 0.00 us
Adaptation value of cylinder 5 for calibration point 800 bar: 0.00 us
Adaptation value of cylinder 1 for calibration point 800 bar: 0.00 us
Adaptation value of cylinder 4 for calibration point 300 bar: 0.00 us
Adaptation value of cylinder 2 for calibration point 300 bar: 0.00 us
Adaptation value of cylinder 6 for calibration point 300 bar: 0.00 us
Adaptation value of cylinder 3 for calibration point 300 bar: 0.00 us
Adaptation value of cylinder 5 for calibration point 300 bar: 0.00 us
Adaptation value of cylinder 1 for calibration point 300 bar: 0.00 us
Specified delivery rate, fuel pump: 0 L/h
Pressure drop at fuel filter: -22.68 bar
Rail pressure fluctuations: 0.0 bar
Vehicle speed: 0 km/h
Diesel Particulate filter (DPF) differential pressure sensor: 0 hPa
Kickdown: Not actuated
Charge air temperature sensor: 0 °C
On/off ratio of exhaust gas recirculation: 0 %
Intake port shutoff actuator motor (Specified): -5 .. 5
On/off ratio of intake port shutoff: 0 %
Throttle valve actuator: 0 %
Temperature sensor upstream of particulate filter: -273 °C
Wastegate control pressure transducer: 0 %
Air filter downstream pressure sensor: 0 hPa
Odometer: 0 km
Exhaust gas recirculation rate: 0.00 %
Inhibit of engine start by crash event: Not active
Circuit 87/4: 0.00 V
Circuit 87/3: 0.00 V
Circuit 87/1: 0.00 V
Data status: --
Serial number of drive authorization system: --
Catalytic converter upstream temperature: -273 °C
Temperature sensor upstream of turbocharger: 0 °C
Distance from last ash content correction: 0 km
Ash content of particulate filter: -- g
Distance since last particulate filter regeneration: 0 km
Soot content of particulate filter: 0.0 g
Fill level of particulate filter: 0 %
Diesel Particulate filter (DPF) regeneration: 0
Engine operating condition: Normal operation without regeneration of DPF
EGR cooler bypass valve: Not actuated
Exhaust flap valve control: 0 %
Low-pressure turbocharger boost pressure sensor: 0.0 hPa
Boost pressure positioner - duty cycle: 0 %
Glow output: --
Actuators test
Controls
Throttle valve actuator
Inlet port shutoff
Exhaust gas recirculation
EGR cooler bypass valve
Engine oil pump valve
Oil spray nozzle shutoff valve
Injectors
Glow output stage
High-pressure exhaust gas turbocharger guide vanes actuator motor
Engine compressions test
Wastegate control pressure transducer
Utility
Controls
Fuel pump activate
Injectors replacement
Teaching process of HFM air flow sensor
Teaching process of inlet port shutoff actuator motor
Teaching process of boost pressure regulator
Teaching process of pressure regulating valve
Teaching process of quantity control valve
Pressure differential sensor teaching
Resetting event memory for loss of synchronization between crankshaft and camshaft
Teaching process of temperature sensors sensor unit
Oxidation catalytic converter initialization
Determination of fill level of diesel particulate filter
DPF regeneration (while driving)
Configuration
Controls
Implicit coding