Car, MERCEDES, VITO, VIANO 639, 639.811, -2008 DE, OM642 - CDI6 NFZ (CDI)
OM642 - CDI6 NFZ (CDI) - 0
Identification
Diagnostic version: 02 04 1A
Boot software number: 33.1.2
Hardware version: 8.44.0
Software version: 11.4.0
Software version 1: 11.28.0
Software version 2: 9.30.0
Supplier: Bosch
Hardware part number: 0054469440
Software part number (customer): 6429023601
Software part number (code): 6429032603
Software part number (data): 6429040100
Serial number: --
VIN no: WDB9066571S324037
VIN stored:
DTC
Controls
Clear DTC
Data stream
Terminal 87/1: 498 V
Terminal 87/2: 504 V
Fuel rail pressure sensor: 498 bar
Boost pressure sensor: 123 hPa
Barometric pressure sensor: 18581 hPa
Battery voltage: 12.1 V
Oil level: 31.0
Exhaust back pressure: -32220 hPa
Diesel Particulate filter (DPF) differential pressure: 1111 hPa
MAP sensor: 30275 hPa
Exhaust gas temperature pre particulate filter: 353 °C
Terminal 15: Yes
Terminal 50 (input): Yes
Transmission position p, N: Yes
Starter lockout: Yes
Fuel tank level: 113 L
Camshaft and crankshaft synchronization: Yes
Terminal 50 (output, starter actuation): Yes
Engine speed: 10 rpm
Current gear: N
Injection quantity: -278 mm³
Engine oil temperature sensor: 2655 °C
Fuel temperature sensor: 611 °C
Fuel pump activation status: Deactivated
Fuel pump: Yes
Camshaft position adaptation status: 3 °
Pressure control solenoid valve: 18 %
Fuel quantity control valve: 27 %
Engine speed: 0 rpm
Intake air temperature sensor: -3111 °C
Coolant temperature: 90 °C
Pedal value sensor: 2 %
Boost air temperature sensor: 323 °C
Mass air flow sensor: 1317 mg
Inlet port shutoff: 128 %
Left intake port shutoff end position measurement sensor: Closed
Right intake port shutoff end position measurement sensor: Open
Kickdown recognition: No
On/off ratio of fan actuation: -328 %
Throttle valve: 10 %
On/off ratio of exhaust gas recirculation: -346 %
Solenoid valve 'Exhaust gas recirculation cooling': 8187.0
Charge pressure positioner: 360 %
Air cleaner soiling: 8 %
Diesel Particulate filter (DPF) saturation: 126 %
Diesel Particulate filter (DPF) flow resistance: 3.077 hPa/(m3/h)
Soot content of particulate filter: -225 g
Ash content of particulate filter: -276 g
Distance since last particulate filter regeneration: 0 km
Time for manual regeneration: 15829 sec
Diesel Particulate filter (DPF) distance since last regeneration: 26441 km
Distance from last ash content correction: 33851 km
Exhaust gas temperature before turbocharger: 194 °C
Diesel Particulate filter (DPF) regeneration status: Not active
Soot content of particulate filter (simulated value): 0 g
Torque requested by driver: -1471 N·m
Torque limitation: -1601 N·m
Engine torque: -1601 N·m
Maximum torque: -187 %
Torque at transmission input: -2401 N·m
Clutch switch: No
Generator voltage: -240 V
Generator voltage: -284 V
Quantity correction values of smooth-running control
Injector cylinder 1: BIBALBA
Injector cylinder 2: BNGSWAA
Injector cylinder 3: GSDHLCA
Injector cylinder 4: AEBAGBA
Injector cylinder 5: FZFXO8C
Injector cylinder 6: GZKSED2
Smooth running of cylinder 1: 0.00
Smooth running of cylinder 4: 0.00
Smooth running of cylinder 2: 0.00
Smooth running of cylinder 5: 0.00
Smooth running of cylinder 3: 0.00
Smooth running of cylinder 6: 0.00
Immobilizer
Engine control module: activated: Yes
Synchronization of engine control module and EIS(ESZ): No
Start enable has been issued by the DAS: Yes
Engine control module test counter: F1 A2
Engine control module: initialized: Yes
Engine control module: transport protection detached: Yes
Engine control module: personalized: Yes
Actuators test
Controls
MIL lamp
Fan
Crankcase ventilation system heating element
Boost pressure actuator
EGR cooler bypass valve
Fuel pump
Fuel filter heater
Injectors
Engine compressions test
Throttle valve actuator
Glow output stage
EGR valve
Utility
Controls
New diesel particulate filter teaching
Used diesel particulate filter teaching
Teaching process of throttle valve stop
Pressure differential sensor teaching
Reset lambda adaptive value
Teaching process of EGR actuator
Pressure control valve teaching
Reset quantity mean value adaptation data
Reset values for HFM drift compensation
Reset fill factor of air filter
Teaching process of AdBlue metering valve
NOx sensor 1 reset
NOx sensor 2 reset
SCR catalytic converter initialization
Diesel oxidation catalytic converter teaching
SCR catalytic converter teaching
Temperature sensor upstream of SCR catalytic converter teaching
Fuel pump activate
Injectors replacement
Edit VIN
DPF regeneration (vehicle stationary)
Diesel particulate filter replacement
Configuration
Controls
Edit configuration