Car, MERCEDES, EQA 243, 243.709 EQA 300 4MATIC, Charger (SG-LG)

Power source control - Charger (SG-LG) - 0

Identification

Diagnostic version: 00 03 09

Boot software number: --

Hardware version: 0.0.0

Software version: --

Software version 1: --

Software version 2: --

Supplier: --

Hardware part number:

Software part number (customer): --

Software part number (code): --

Software part number (data): --

Serial number: --

DTC

P010000: Mass or volume air flow (MAF) sensor 1/A - electrical fault

Controls

Clear DTC

Data stream

Circuit 30: -- V

Circuit 30c: -- V

High-voltage on-board electrical system voltage: -- V

Measured voltage value at input of alternating current charger for high-voltage battery control unit: -- V

Charging current (alternating current): -- A

Charging current (alternating current) of phase 1: -- A

Charging current (alternating current) of phase 2: -- A

Charging current (alternating current) of phase 3: -- A

Maximum charging current (alternating current): -- A

Temperature in alternating current charger for high-voltage battery: -- °C

Heat exchanger temperature: -- °C

Charging cable locking: --

Vehicle socket status: --

Odometer: -- km

High-voltage component lock in alternating current charger for high-voltage battery: --

Interlock circuit on alternating current charger for high-voltage battery: --

Actuators test

Controls

High-voltage component lock