Car, MERCEDES, Sprinter 906, 906.213, 2013-, Parameterizable special module (PSM)

Special multifunction module - Parameterizable special module (PSM) - 0

Identification

MB number for hardware: 9064467821

Diagnostic version: 3.5

Hardware number: 07.30

Software number: 07.34

Supplier: Borg

Diagnostic version: 03 05

DTC

9809: PSM functionality 'Central locking' - Right sliding door could not be unlocked

Controls

Clear DTC

Data stream

Voltage terminal 30.1: 2 V

Voltage terminal 30.2: 60 V

Analog inputs: input 07: 2 V

Analog inputs: input 08: 38 V

Analog inputs: input 09: 51 V

Analog inputs: input 10: 43 V

Digital inputs: input 01: Operated

Digital inputs: input 02: Not operated

Digital inputs: input 03: Operated

Digital inputs: input 04: Not operated

Digital inputs: input 05: Operated

Digital inputs: input 06: Not operated

Digital inputs: input 07: Operated

Digital inputs: input 08: Not operated

Digital inputs: input 09: Operated

Digital inputs: input 10: Not operated

Output current values: output 01 (coded as 'High side'): 34 A

Output current values: output 01 (coded as 'Low side'): 19 A

Output current values: output 02 (coded as 'High side'): 11 A

Output current values: output 02 (coded as 'Low side'): 19 A

Output current values: output 03: 37 A

Output current values: output 04: 5 A

Output current values: output 05: 39 A

Output current values: output 06: 35 A

Output current values: output 07: 30 A

Output current values: output 08: 21 A

Output current values: output 09: 18 A

Output current values: output 10: 52 A

Output current values: output 11: 48 A

Output current values: output 12: 18 A

PWM outputs output 09 (Raw value): FF 00

PWM outputs output 10 (Raw value): 00 FF

Digital outputs: output 01: Actuated

Digital outputs: output 02: Not actuated

Digital outputs: output 03: Actuated

Digital outputs: output 04: Not actuated

Digital outputs: output 05: Actuated

Digital outputs: output 06: Not actuated

Digital outputs: output 07: Actuated

Digital outputs: output 08: Not actuated

Digital outputs: output 11: Actuated

Digital outputs: output 12: Not actuated

Digital outputs: output 13: Actuated

Digital outputs: output 14: Not actuated

Digital outputs: output 15: Actuated

Digital outputs: output 16: Not actuated

Digital outputs: output 17: Actuated

Digital outputs: output 18: Not actuated

Digital outputs: output 19: Actuated

Digital outputs: output 20: Not actuated

Body CAN bus: fuel consumption (Resolution: 0.1 L): 49465 L

Body CAN bus: fuel consumption (Resolution: 0.001 L): 4011081.000 L

Body CAN bus: operating hours counter: 476805.75 H