Bil, MERCEDES, SMART 451 elektro Phase 2, Tire pressure monitor (TPM)

Dæk tryks overvågning - Tire pressure monitor (TPM) - 0

Identifikation

MB number for hardware: 9068300785

Diagnose version: 0.0

Hardware number: 06.40

Software nummer: 05.44

Supplier: Ikke defineret

Diagnose version: 00 00

Fejlkoder

C011: CAN-bus off failure

Controls

Clear DTC

Levende Data

Front or rear sensor localization: Successfully ended

Left or right sensor localization: Mislykket

Left front wheel electronics identification number: 12 23 34 45

Right front wheel electronics identification number: 56 67 78 89

Right rear wheel electronics identification number: 9A AB BC CD

Left rear wheel electronics identification number: DE EF F1 12

Front axle tire pressure specified value: 4 bar

Rear axle tire pressure specified value: 6 bar

Activation memory

Activation no. 1: tire pressure (Wheel electronics no. 1): 6 bar

Activation no. 1: tire pressure (Wheel electronics no. 2): 2 bar

Activation no. 1: tire pressure (Wheel electronics no. 4): 5 bar

Activation no. 1: tire pressure (Wheel electronics no. 3): 5 bar

Activation no. 1: tire temperature (Wheel electronics no. 1): 147.0 °C

Activation no. 1: tire temperature (Wheel electronics no. 2): 176.0 °C

Activation no. 1: tire temperature (Wheel electronics no. 4): 143.0 °C

Activation no. 1: tire temperature (Wheel electronics no. 3): 117.0 °C

Activation no. 1: ambient temperature: 26.5 °C

Activation no. 1: kilometer reading: 1048064.0 km

Activation no. 1: activation sequence: Ukendt

Activation no. 1: result: Activation was unsuccessful

Activation no. 2: tire pressure (Wheel electronics no. 1): 1 bar

Activation no. 2: tire pressure (Wheel electronics no. 2): 1 bar

Activation no. 2: tire pressure (Wheel electronics no. 4): 3 bar

Activation no. 2: tire pressure (Wheel electronics no. 3): 0 bar

Activation no. 2: tire temperature (Wheel electronics no. 1): 98.0 °C

Activation no. 2: tire temperature (Wheel electronics no. 2): 17.0 °C

Activation no. 2: tire temperature (Wheel electronics no. 4): 36.0 °C

Activation no. 2: tire temperature (Wheel electronics no. 3): 64.0 °C

Activation no. 2: ambient temperature: -37.5 °C

Activation no. 2: kilometer reading: 737328.0 km

Activation no. 2: activation sequence: Activation via component Switches

Activation no. 2: result: Activation was completed successfully

Activation no. 3: tire pressure (Wheel electronics no. 1): 3 bar

Activation no. 3: tire pressure (Wheel electronics no. 2): 1 bar

Activation no. 3: tire pressure (Wheel electronics no. 4): 0 bar

Activation no. 3: tire pressure (Wheel electronics no. 3): 1 bar

Activation no. 3: tire temperature (Wheel electronics no. 1): 87.0 °C

Activation no. 3: tire temperature (Wheel electronics no. 2): -41.0 °C

Activation no. 3: tire temperature (Wheel electronics no. 4): 50.0 °C

Activation no. 3: tire temperature (Wheel electronics no. 3): -15.0 °C

Activation no. 3: ambient temperature: -6.5 °C

Activation no. 3: kilometer reading: 425152.0 km

Activation no. 3: activation sequence: Automatic activation

Activation no. 3: result: Activation was unsuccessful

Activation no. 4: tire pressure (Wheel electronics no. 1): 1 bar

Activation no. 4: tire pressure (Wheel electronics no. 2): 1 bar

Activation no. 4: tire pressure (Wheel electronics no. 4): 0 bar

Activation no. 4: tire pressure (Wheel electronics no. 3): 3 bar

Activation no. 4: tire temperature (Wheel electronics no. 1): -31.0 °C

Activation no. 4: tire temperature (Wheel electronics no. 2): 115.0 °C

Activation no. 4: tire temperature (Wheel electronics no. 4): 34.0 °C

Activation no. 4: tire temperature (Wheel electronics no. 3): -15.0 °C

Activation no. 4: ambient temperature: 3.0 °C

Activation no. 4: kilometer reading: 30864.0 km

Activation no. 4: activation sequence: Automatic activation

Activation no. 4: result: Activation was unsuccessful

Activation no. 5: tire pressure (Wheel electronics no. 1): 1 bar

Activation no. 5: tire pressure (Wheel electronics no. 2): 1 bar

Activation no. 5: tire pressure (Wheel electronics no. 4): 3 bar

Activation no. 5: tire pressure (Wheel electronics no. 3): 3 bar

Activation no. 5: tire temperature (Wheel electronics no. 1): 139.0 °C

Activation no. 5: tire temperature (Wheel electronics no. 2): 160.0 °C

Activation no. 5: tire temperature (Wheel electronics no. 4): -7.0 °C

Activation no. 5: tire temperature (Wheel electronics no. 3): 2.0 °C

Activation no. 5: ambient temperature: 3.5 °C

Activation no. 5: kilometer reading: 138176.0 km

Activation no. 5: activation sequence: Ukendt

Activation no. 5: result: Activation was completed successfully

Udgangs test

Controls

Left front signal transfer test

Right front signal transfer test

Left rear signal transfer test

Right rear signal transfer test

Muligheder

Controls

Wheel electronics identification number