Car, MERCEDES, SMART 451, 451.401, Sprintshift control module (SSCM)
Transaxle - Sprintshift control module (SSCM) - 0
Identification
MB number for hardware: 4515454132
Diagnostic version: 0.5
Hardware number: 13.06
Software number: 00.34
Supplier: Not defined
Diagnostic version: 00 05
VIN no (original): WME4513321K234946
VIN no: WME4513321K234946
DTC
Controls
Clear DTC
Data stream
VIN no (original): WME4513321K234946
VIN no: WME4513321K234946
Original VIN writing status: Interlocked
Serial number: 22 08 53 00 00 51
Battery voltage: 12 V
Actual gear: Neutral
Clutch status: Open
Clutch protection class 3: 34855
Actual clutch position: 61200 inch
Specified clutch position: 60720
Average clutch drag point: 25588 lnk
Maximum end stop clutch position: 410
Mileage of clutch: 70 km
Clutch: 4715 W
Power loss of clutch: 2805
Power loss of clutch: 1180 W
Power loss of clutch: 187535
Clutch protection class: 25
Counter for clutch protection class 1: 37155
Counter for clutch protection class 2: 58181
Time in clutch protection class 3: 33427 min
Counter for clutch protection class 3: 39192
Left front wheel speed sensor: 19596 rpm
Right front wheel speed sensor: 28834 rpm
Fault selector drum movement: Fault while engaging gear
Left rear wheel speed sensor: 4514 rpm
Right rear wheel speed sensor: 10777 rpm
Fault transmission: Emergency running
Speed of driven axle: 0.00 km/h
Speed of non-driven axle: 0.00 km/h
Gear position (current): Neutral
Transmission input speed: 47890 rpm
Transmission output speed: 52376 rpm
Gear position (target): Gear 1
Engine speed: 0 rpm
Selector lever raw value: 17
Selector lever: Neutral
Program selector switch: Not operated
Position of selector drum 1: 90.0000 °
Position of selector drum 2: 0.0000 °
Position of selector drum 1 (Down): 1.12 °
Position of selector drum 1 (Up): 230.12 °
Position of selector drum 2 (Down): 2.06 °
Position of selector drum 2 (Up): 235.00 °
Transmission temperature: 105 °C
Engine temperature: 190 °C
Fault status selector drum movement 1: Wiring fault
Fault status selector drum movement 2: No reaction
Learning status selector drum movement 1: The actual value is not within the permissible range
Learning status selector drum movement 2: Internal time-out
Automated manual transmission relay: 34.57 V
Automated manual transmission relay (Output): 145.50 V
Status relay SEQ: On
Utility
Controls
Learn clutch
Open clutch
Close clutch
Function test 1, 2 (Automatic test)
Function test 3
Teach transmission
Switch on relay Transmission
Shift into individual gears
Energize transmission with specified value (Transmission motor 1)
Energize transmission with specified value (Transmission motor 2)