Car, MERCEDES, S 221, 221.195 S 400 HYBRID L, Stationary heater (STH)
Climate control - Stationary heater (STH) - 0
Identification
MB number for hardware: 2215061098
Diagnostic version: 18.4
Hardware number: 07.02
Software number: 08.33
Supplier: Webasto
Diagnostic version: 12 04
DTC
9151: Fault interlock has been activated
Controls
Clear DTC
Data stream
Power supply: 12 V
Water temperature: 80 °C
CO2 setting of combustion air blower: 192
Stationary heater in heating mode: Active
Stationary heater in ventilation mode: Not active
STH or HB heater unit: Active
Operating state: Control interval
STH switchover valve: Not active
STH switchover valve on/off ratio: 51.0
A6m2 (combustion air blower): Not active
Flame monitor glowpin unit: Not active
Flame monitor glowpin unit on/off ratio: 96.0
Flame monitor glowpin unit has flame detected: Yes
STH fuel metering pump: Not active
STH fuel metering pump: 0.510 sec
On signal to telestart receiver: Not active
Off signal to telestart receiver: Not active
N72/1s30 (STH/HB [ZUB]/residual heat button): Not operated
On signal from the telestart receiver: No
Off signal from the telestart receiver: No
Actuators test
Controls
Switch on stationary heater (normal mode)
Switch on stationary heater (test mode)
Heating/Switch on ventilation in line with request from AC pushbutton control module
Configuration
Controls
Edit configuration