Car, MERCEDES, R 251, 251.062 R 280 4MATIC, Automatic air conditioning (AAC)
Climate control - Automatic air conditioning (AAC) - 0
Identification
MB number for hardware: 2518206489
Diagnostic version: 0.37
Hardware number: 07.14
Software number: 07.45
Supplier: Hella
Diagnostic version: 00 25
DTC
Event 900E: Terminal 30 - low voltage
9403: Rear shutoff flap motor - LIN bus communication error
9604: PTC - no communication (LIN)
Controls
Clear DTC
Data stream
Fresh/recirculation air flap motor: 100 %
Fresh/recirculation air flap motor - target value: 100 %
Fresh/recirculation air flap motor: 1611 steps
Fresh/recirculation air flap motor - target value: 1611 steps
Fresh and recirculated air flaps adjustment motor - stored travel: 1611 steps
Current fresh and recirculated air flaps - adjustment motor travel: 1611 steps
Fresh and recirculation air flaps motor - manufacturer: Elmos/Saia
Left air mix flap motor - position: 88 %
Air mix flap motor - target left position: 89 %
Left air mix flap motor - position: 1207 steps
Air mix flap motor - target left position: 1212 steps
Left air mix flap adjustment motor - stored travel: 1362 steps
Current left air mix flap adjustment motor travel: 1362 steps
Left air mix flap motor - manufacturer: Elmos/Saia
Right air mix flap actuator motor - position: 91 %
Right air mix flap actuator motor - target position: 91 %
Right air mix flap actuator motor - position: 1126 steps
Right air mix flap actuator motor - target position: 1131 steps
Right air mix flap adjustment motor - stored travel: 1238 steps
Right air mix flap adjustment motor - current travel: 1238 steps
Right air mix flap motor - manufacturer: Elmos/Saia
Rear shutoff flap actuator motor - position: 68 %
Rear shutoff flap actuator motor - target position: 68 %
Rear shutoff flap actuator motor - position: 1914 steps
Rear shutoff flap actuator motor - target position: 1921 steps
Rear shutoff flap adjustment motor - stored travel: 2800 steps
Rear shutoff flap adjustment motor - current travel: 2800 steps
Rear shutoff flap motor - manufacturer: Elmos/Saia
Center ventilation air flap actuator motor - position: 59 %
Center ventilation air flap actuator motor - target position: 59 %
Center ventilation air flap actuator motor - position: 855 steps
Center ventilation air flap actuator motor - target position: 852 steps
Center ventilation air flap adjustment motor - stored travel: 1431 steps
Center ventilation air flap adjustment motor - current travel: 1431 steps
Center ventilation air flap motor - manufacturer: Not used
Left and right footwell flaps motor - position: 100 %
Footwell flaps motor - target left and right position: 100 %
Left and right footwell flaps motor - position: 1050 steps
Footwell flaps motor - target left and right position: 1050 steps
Left and right footwell flaps adjustment motor - stored travel: 1050 steps
Current left and right footwell flaps adjustment motor travel: 1050 steps
Left and right footwell flaps motor - manufacturer: Elmos/Saia
Left and right defroster flaps motor - position: 100 %
Defroster flaps motor - target left and right position: 100 %
Left and right defroster flaps motor - position: 1467 steps
Defroster flaps motor - target left and right position: 1467 steps
Left and right defroster flaps adjustment motor - stored travel: 1467 steps
Current left and right defroster flaps adjustment motor travel: 1467 steps
Left and right defroster flaps motor - manufacturer: Elmos/Saia
Rear air distribution flap actuator motor - position: 0 %
Rear air distribution flap actuator motor - target position: 0 %
Rear air distribution flap actuator motor - position: 0 steps
Rear air distribution flap actuator motor - target position: 0 steps
Rear air distribution flap adjustment motor - stored travel: 832 steps
Rear air distribution flap adjustment motor - current travel: 832 steps
Rear air distribution flap motor - manufacturer: Elmos/Saia
Interior air temperature sensor: 23 °C
Ambient temperature sensor: 22 °C
Front evaporator - temperature: 22 °C
Left side outlet temperature sensor: 24 °C
Right side outlet temperature sensor: 21 °C
Left footwell temperature sensor: 20 °C
Right footwell temperature sensor: 18 °C
Left center outlet temperature sensor: 35 °C
Right center outlet temperature sensor: 35 °C
Center rear interior temperature sensor: 24 °C
Refrigerant pressure: 2 bar
Sun sensor - light intensity: 255 %
Terminal 30: 14 V
Supply voltage for sensor: 5 V
A/C compressor request: 0 %
Engine coolant temperature sensor: 91 °C
Engine speed: 637 rpm
Rear air conditioning refrigerant shutoff valve: Off
Heating water circulation pump: On
Compressor - status or cause for compressor cutout: Button 'OFF' operated
Front blower capacity: 0 %
Front blower supply voltage: 0 V
Front blower motor: 0 A
Actuators test
Controls
Fresh and recirculation air flaps motor
Left air mix flap motor
Right air mix flap motor
Rear shutoff flap positioning motor
Left and right defroster flaps motor
Left and right footwell flaps motor
Center ventilation flap motor
Diverter flap actuator motor
Rear air distribution flap positioning motor
Blower motor
Electric suction fan
Illumination
AC compressor
Heating water circulation pump
Closing air recirculation flap (for cleaning)