Car, MERCEDES, R 251, 251.157 R 350 LL 4MATIC, Stationary heater (STH)
Climate control - Stationary heater (STH) - 0
Identification
MB number for hardware: 2218705187
Diagnostic version: 2.1
Hardware number: 06.27
Software number: 06.43
Supplier: Temic
Diagnostic version: 02 01
DTC
9053: Flame has gone out more than 4 times during the heating cycle
Controls
Clear DTC
Data stream
Supply voltage: 10 V
Water temperature: 101 °C
CO2 setting of combustion air blower: 129
Stationary heater in heating mode: Active
Stationary heater in ventilation mode: Active
STH heater unit: Active
Operating state: Part load
STH switchover valve: Active
STH switchover valve on/off ratio: 96
Combustion air blower: Active
Off signal to telestart receiver: Active
Fuel preheating system: Active
Fuel preheating system on/off ratio: 23
Flame monitor glowpin unit: Active
Flame monitor glowpin unit on/off ratio: 85
Flame monitor glowpin unit has flame detected: Yes
Auxiliary heater metering pump: Active
Auxiliary heater metering pump period: 1.170 sec
On signal to telestart receiver: Active
STH switch: Operated
Number of teach-in processes in STH radio remote control receiver: 11
On signal from the telestart receiver: Yes
Off signal from the telestart receiver: Yes
Configuration
Controls
Edit configuration