Bil, MERCEDES, GLE 167, 167.148 GLE 350, Integrated starter generator (ISA)
Strøm kilde kontrol - Integrated starter generator (ISA) - 0
Identifikation
Diagnose version: 00 00 05
Boot software number: --
Hardwareversion: --
Softwareversion: --
Software version 1: --
Software version 2: --
Supplier: --
Hardware vare nummer:
Software part number (customer): --
Software part number (code): --
Software part number (data): --
Serie nummer: --
Stel nr.:
VIN stored:
Fejlkoder
P061A00: Torque control of control unit - malfunction
Controls
Clear DTC
Levende Data
Coolant from network: 216.00 °C
PN48 (KL40): 0.00 V
PN14 (KL30): 0.00 V
PN48 (KL40) from network: 0.00 V
PN14 (KL30) from network: 0.00 V
Voltage request: 0.00 V
Maximum charge voltage: 0.00 V
Minimum discharge voltage: 0.00 V
PN48 (KL40) from network: -500.00 A
Minimum charge current: -819.00 A
Maximum discharge current: 0.00 A
Discharge current max offset: -254.00 A
30C faulty: FALSK
Interlock faulty: FALSK
Cam sync faulty: FALSK
CCB Switch from network: Lukket
DCB Switch from network: Lukket
Speed request: 0.00 Omdr.
Machine state: Standby
Mode: Tomgang
Torque request - maximum: -512.00 N·m
Torque request - minimum: -512.00 N·m
Emergency request: Tomgang
Performance limitation request: No request
Torque reduction state: No derating
Statspærretilstand: Udløst
MIL request: FALSK
Crash error:
Interlock circuit error:
PN14 (KL30) undervoltage: Ubestemt
DC-link voltage too low: Nej
Immobilizer not released: Nej
DC-link voltage out of range: Nej
Speed out of range: Nej
Speed direction negative: Nej
Ignition status: Ignition key inserted
DidA external tester present: Ikke tilstede
Engine running status: Motor stoppet
Supply battery cutoff switch state: Lukket
Powernet transport mode: Permanently off
1.3V faulty: FALSK
3.3V faulty: FALSK
5V 'S' (for current sensor) faulty: FALSK
5V 'A' (for high accuracy) faulty: FALSK
5V faulty: FALSK
14V faulty: FALSK
OFFSET: 0.00 °
General denominator (IUMPR): 0
Tændingscyklustæller: 0
Konfiguration
Controls
Variant coding
Exhaust regulation/Type approval number