Car, MERCEDES, E 211, 211.076 E 55 Compressor AMG, 2005-2006, Automatic air conditioning (AAC)
Climate control - Automatic air conditioning (AAC) - 0
Identification
Production date: 06 10 11
Hardware number: 01.06
Software number: 10.06
Diagnostic version: 4.7
MB number for hardware: 16 95 45 19 08
Supplier: Kostal
Identifier: 04 07
DTC
9350: Communication error of AC bus with C-AAC multifunction sensor
9465: Blower regulator overload shutdown
9460: Communication error of AC bus with right air mix flap motor
Controls
Clear DTC
Data stream
Evaporator temperature sensor: -99 °C
OCP: N70b1 (in-car temperature sensor): 22 °C
In-car temperature sensor: -99 °C
Ambient temperature sensor: 31 °C
Refrigerant pressure: 18 bar
Engine speed: 751
Request to A/C compressor: 0 %
A/C compressor torque: 0 N·m
A/C compressor current consumption: 0 mA
Engine coolant temperature sensor: 255 °C
Left front sun sensor light intensity: 0 %
Right front sun sensor light intensity: 0 %
Left rear sun sensor light intensity: 0 %
Right rear sun sensor light intensity: 0 %
C-AAC sun sensor (4 in total) total light intensity: 0 %
Terminal 58d: 0 %
Vehicle speed sensor: 0 km/h
Target left air mix flap motor position: 20534
Left air mix flap motor position: -9997
Stored left air mix flap adjustment motor travel: 1913
Current left air mix flap adjustment motor travel: 1915
Lost communication between AAC pushbutton control module and left air mix flap motor: Yes
Left air mix flap motor electrical fault: No
Left air mix flap motor mechanical fault: Yes
Left air mix flap motor excess temperature: No
Left air mix flap motor position motors alignment: Ok
Target right air mix flap actuator motor position: -9923
Right air mix flap actuator motor position: -9817
Stored right air mix flap adjustment motor travel: 1956
Current right air mix flap adjustment motor travel: 1907
Lost communication between AAC pushbutton control module and right air mix flap motor: Yes
Right air mix flap motor electrical fault: No
Right air mix flap motor mechanical fault: Yes
Right air mix flap motor excess temperature: No
Right air mix flap motor position motors aligment: Ok
Target left defroster flap motor position: -7624
Left defroster flap actuator motor position: 12965
Stored left defroster flap adjustment motor travel: 31541
Current left defroster flap adjustment motor travel: 45351
Lost communication between AAC pushbutton control module and left defroster flap motor: No
Left defroster flap actuator electrical fault: Yes
Left defroster flap motor mechanical fault: No
Left defroster flap actuator excess temperature: Yes
Left defroster flap actuator position motors aligment: Ok
Target right defroster flap motor position: 24919
Right defroster flap motor position: 12572
Stored right defroster flap adjustment motor travel: 49252
Current right defroster flap adjustment motor travel: 37175
Lost communication between AAC pushbutton control module and right defroster flap motor: Yes
Right defroster flap actuator electrical fault: No
Right defroster flap motor mechanical fault: Yes
Right defroster flap actuator excess temperature: No
Right defroster flap actuator position motors alignment: Ok
Target right footwell flap motor position: 24883
Right footwell flap motor position: 36229
Stored right footwell flap adjustment motor travel: 49705
Current right footwell flap adjustment motor travel: 41512
Lost communication between AAC pushbutton control module and right footwell flap motor: Yes
Right footwell flap motor electrical fault: No
Right footwell flap motor mechanical fault: Yes
Right footwell flap motor excess temperature: No
Right footwell flap motor position motor alignment: Ok
Target left footwell flap actuator motor position: 23138
Left footwell flap motor position: -3817
Stored left footwell flap adjustment motor travel: -7929
Current left footwell flap adjustment motor travel: 2142
Lost communication between AAC pushbutton control module and left footwell flap motor: Yes
Left footwell flap actuator electrical fault: No
Left footwell flap motor mechanical fault: Yes
Left footwell flap actuator excess temperature: No
Left footwell flap actuator position motor alignment: Ok
Target right center ventilation air flap motor position: 296
Right center ventilation air flap motor position: -3454
Stored right center ventilation air flap adjustment motor travel: 49704
Current right center ventilation air flap adjustment motor travel: 42340
Lost communication between AAC pushbutton control module and right center ventilation air flap motor: Yes
Right center ventilation air flap motor electrical fault: No
Right center ventilation air flap motor mechanical fault: Yes
Right center ventilation air flap motor excess temperature: No
Right center ventilation air flap motor position motor alignment: Ok
Target left center ventilation air flap motor position: 29256
Left center ventilation air flap actuator motor position: 20534
Stored left center ventilation air flap adjustment motor travel: 29208
Current left center ventilation air flap adjustment motor travel: 2726
Lost communication between AAC pushbutton control module and left center ventilation air flap motor: Yes
Left center ventilation air flap motor electrical fault: No
Left center ventilation air flap motor mechanical fault: Yes
Left center ventilation air flap motor excess temperature: No
Left center ventilation air flap motor position motor alignment: Ok
Target value of fresh/recirculation air flap motor: -9997
Fresh/recirculation air flap motor: 15172
Stored fresh and recirculated air flaps adjustment motor travel: 2114
Current fresh and recirculated air flaps adjustment motor travel: 2119
Lost communication between AAC pushbutton control module and fresh and recirculated air flaps motor: Yes
Fresh and recirculation air flaps motor electrical fault: No
Fresh and recirculation air flaps motor mechanical fault: Yes
Fresh and recirculation air flaps motor excess temperature: No
Fresh and recirculation air flaps motor position motor alignment: Ok
Target left rear air mix flap motor position: 45075
Left rear air mix flap motor position: 49447
Stored left rear air mix flap adjustment motor travel: 46691
Current left rear air mix flap adjustment motor travel: 49879
Lost communication between AAC pushbutton control module and left rear air mix flap motor: Yes
Left rear air mix flap motor electrical fault: No
Left rear air mix flap motor mechanical fault: Yes
Left rear air mix flap motor excess temperature: No
Left rear air mix flap motor position motor alignment: Ok
Target right rear air mix flap motor position: 45075
Right rear air mix flap motor position: 52070
Stored right rear air mix flap adjustment motor travel: 41730
Current right rear air mix flap adjustment motor travel: 8501
Lost communication between AAC pushbutton control module and right rear air mix flap motor: Yes
Right rear air mix flap motor electrical fault: No
Right rear air mix flap motor mechanical fault: Yes
Right rear air mix flap motor excess temperature: No
Right rear air mix flap motor position motor alignment: Ok
Target value of blower regurator for requirement of blower capacity: 18 %
Blower motor current consumption: 1.6 A
Blower regulator temperature: 1.0 °C
Blower regulator supply voltage: 12.0 V
Multifunction sensor CO value: 530
Multifunction sensor NOx value: 354
Multifunction sensor dewpoint temperature: 13 °C
Multifunction sensor relative air humidity: 41
Multifunction sensor current ambient temperature: 58 °C
Power supply: 12 V
Left heating capacity: 100 %
Right heating capacity: 100 %
DF signal (Analog): 0 %
Cutoff because of overvoltage at terminal 30: No
Cutoff because of undervoltage at terminal 30: No
Shutdown due to excessive temperature: No
Generator output: Ok
PTC heater booster: Ok
PTC heater booster: 0 A
Heating element 1: short circuit: Not present
Heating element 2: short circuit: Not present
Heating element 3: short circuit: Not present
Heating element 4: short circuit: Not present
Heating element 5: short circuit: Not present
Heating element 6: short circuit: Not present
Heating element 7: short circuit: Not present
Heating element 8: short circuit: Not present
Heating element 1: open circuit: Not present
Heating element 2: open circuit: Not present
Heating element 3: open circuit: Not present
Heating element 4: open circuit: Not present
Heating element 5: open circuit: Not present
Heating element 6: open circuit: Not present
Heating element 7: open circuit: Not present
Heating element 8: open circuit: Not present
Actuators test
Controls
Heater booster
Left defroster flap motor
Right defroster flap motor
Left footwell flap motor
Right footwell flap motor
Left center ventilation air flap actuator motor, Left air mix flap motor
Right center ventilation air flap actuator motor, Right air mix flap motor
Left rear air mix flap motor
Right rear air mix flap motor
Left and right defroster flaps motor
Left and right footwell flaps motor
Center ventilation flap motor
Left and right air mix flaps motor
Fresh and recirculation air flaps motor
Activated charcoal filter flap adjustment motor
Blower motor
Engine/AC electric suction fan
Illumination
Display test images on the LCD display
Check of LEDs
A/C compressor relay
Blower of interior temperature sensor
Heat exchanger shutoff motor
Closing air recirculation flap (for cleaning)