Bil, MERCEDES, C 204, 204.055 C 300 Sedan, Transmission control (VGS)

transakse - Transmission control (VGS) - 0

Identifikation

Diagnose version: 00 08 05

Boot software number: 0.0.0

Hardwareversion: 10.7.0

Softwareversion: 10.32.0

Software version 1: 10.16.0

Software version 2: 10.9.0

Supplier: Continental Automotive GmbH

Hardware vare nummer: 1669011200

Software part number (customer): 1669027501

Software part number (code): 1669033500

Software part number (data): 1669032500

Serie nummer: --

Stel nr.: WDD2042491A907454

VIN stored: WDD2040491A907454

Fejlkoder

U010300: Lost communication with gear shift module "A"

Controls

Clear DTC

Levende Data

Torque converter slip speed: 37253.0 Omdr.

Torque converter lock-up clutch status: Closed to slipping

Position of selection range valve: Initialization value

Transmission mode: Manuelt

Calculated gear: Implausible

Parking position: 3. Gang

Target gear: 1. Gang

Motordrejningsmoment: 402.0 N·m

Output speed: 37250.00 Omdr.

Offroad: Ikke aktiv

Start enable: Aktiv

Oil pressure sensor of wet clutch: Tænd

Clutch grip point: Tænd

Steering wheel shift button 'PLUS': Not actuated

Steering wheel shift button 'MINUS': Not actuated

Current error codes: Nej

NOTLAUF: Nej

Neutral position request: Nej

Kickdown: Aktiv

Internal transmission speed: 45335.00 Omdr.

Gearkassens udgangsomdrejningstal: 37250.00 Omdr.

Turbine speed: 43031.00 Omdr.

Motor Hastighed: 37250.00 Omdr.

Accelerator pedal position sensor: 25

STEIGUNG: 0

Batteri spænding: 11.00 V

Operating mode: Normal modus

Muligheder

Controls

Adaptation via torque ranges

Fill time adaptation of torque converter lockup clutch

Deceleration adaptation

Performing adaptation (SHIFT 1-2)

Performing adaptation (SHIFT 2-3)

Performing adaptation (SHIFT 3-4)

Performing adaptation (SHIFT 4-5)

Performing adaptation (SHIFT 5-6)

Performing adaptation (SHIFT 6-7)

Downshifts

Acceleration downshift from gear 2 to 1

Acceleration downshift from gear 3 to 2

Acceleration downshift from gear 4 to 3

Acceleration downshift from gear 5 to 4

Acceleration downshift from gear 6 to 5

Acceleration downshift from gear 7 to 6

Resetting the adaptation values of shift operations

Resetting the service life data of the torque converter

Switch off incline recognition for dynamometer mode

Konfiguration

Controls

Redigere konfiguration