Bil, CITROEN, C-ZERO, CMU_01

HV Batteri - CMU_01 - 0

Identifikation

ECU origin: Mitsubishi

Hardware number: 00 06

ECU reference: 9499A794

Diagnose version: 00 10

Softwareversion: 02 01 13

Softwareversion: 8634A04904

VIN no (original): --

Motor type: --

Stel nr.: --

Fejlkoder

Controls

Clear DTC

Levende Data

Module voltage: 0.000 V

Cell total voltage: 0.000 V

Voltage diff. (Module-Total cell): 0.000 V

Cell A voltage: 0.000 V

Cell B voltage: 0.000 V

Cell C voltage: 0.000 V

Cell D voltage: 0.000 V

Cell E voltage: 0.000 V

Cell F voltage: 0.000 V

Cell G voltage: 0.000 V

Cell H voltage: 0.000 V

Cell monitor IC: Normal

Sensor voltage: Normal

Reference low voltage: Normal

Reference high voltage: Normal

Temperature sensor 1 (open): Normal

Temperature sensor 2 (open): Normal

Temperature sensor 3 (open): Normal

Temperature sensor 4 (open): Normal

Temperature sensor 5 (open): Normal

Temperature sensor 6 (open): Normal

Temperature sensor 1 (short): Normal

Temperature sensor 2 (short): Normal

Temperature sensor 3 (short): Normal

Temperature sensor 4 (short): Normal

Temperature sensor 5 (short): Normal

Temperature sensor 6 (short): Normal

Cell A voltage underflow: Normal

Cell B voltage underflow: Normal

Cell C voltage underflow: Normal

Cell D voltage underflow: Normal

Cell E voltage underflow: Normal

Cell F voltage underflow: Normal

Cell G voltage underflow: Normal

Cell H voltage underflow: Normal

Cell B voltage overflow: Normal

Cell A voltage overflow: Normal

Cell C voltage overflow: Normal

Cell D voltage overflow: Normal

Cell E voltage overflow: Normal

Cell F voltage overflow: Normal

Cell G voltage overflow: Normal

Cell H voltage overflow: Normal

Temperature sensor 1 underflow: Normal

Temperature sensor 2 underflow: Normal

Temperature sensor 3 underflow: Normal

Temperature sensor 4 underflow: Normal

Temperature sensor 5 underflow: Normal

Temperature sensor 6 underflow: Normal

Temperature sensor 1 overflow: Normal

Temperature sensor 2 overflow: Normal

Temperature sensor 3 overflow: Normal

Temperature sensor 4 overflow: Normal

Temperature sensor 5 overflow: Normal

Temperature sensor 6 overflow: Normal

EEPROM Fail (Learning data read): Normal

CAN controller: Normal

Cell A connection terminal: Normal

Cell C connection terminal: Normal

Cell E connection terminal: Normal

Cell G connection terminal: Normal

A/D conversion (Reference VOLT.): Normal

A/D conversion (Temperature sensor 1): Normal

A/D conversion (Temperature sensor 2): Normal

A/D conversion (Temperature sensor 3): Normal

A/D conversion (Temperature sensor 4): Normal

A/D conversion (Temperature sensor 5): Normal

A/D conversion (Temperature sensor 6): Normal

A/D conversion (Module voltage): Normal