Bil, CITROEN, C5 (X7), 9HZ - EDC16C3
9HZ - EDC16C3 - 0
Identifikation
PSA reference: 96 53 95 89 80
ECU manufacturer: Bosch
Additional number: 96 64 61 80 80
Softwareversion: 01 01
Software reference: 62 87 76
Fejlkoder
P0299: Turbocharger boost pressure regulation circuit pressure too low
Controls
Clear DTC
DPF information
Inlet air temperature at manifold: 47.7 °C
Køretøjets hastighed sensor: 0 km/h
Motor kølevæske temperatur føler: 62.6 °C
Additive adding system fault: Addition of additive not possible
Air flow volume: 0.0 kg/h
Motor Hastighed: 0.0 Omdr.
Catalytic converter downstream temperature: 105.9 °C
Exhaust gas differential pressure: 0.0 mbar
Intake air temperature sensor: 48 °C
Diesel Particulate filter (DPF) soot mass: 18.4 %
Average distance between the last 5 regenerations: 231.1 km
Diesel Particulate filter (DPF) distance since last regeneration: 410.9 km
Weight of additive in the PEF: 100.0 g
Volume of additive remaining in the reservoir: 1275.0 ml
Levende Data
Additional heater: Inaktiv
Inlet air temperature at manifold: 47.7 °C
Indlæringstilstand: Last EGR valve programming correct; First EGR vlve programming correct; Last EGR butterfly programming correct; First EGR butterfly programming correct; Last air heating butterfly programming correct; ; ;
First air heater throttle learning value: Korrekt
Barometrisk tryk føler: 1.000 bar
Turbo pressure: 1.000 bar
Brake pedal switch 1: Udløst
Brake pedal switch 2: Udløst
A/C authorisation: Nej
A/C pressure: Normal
Køretøjets hastighed sensor: 0 km/h
Clutch pedal: Udløst
Gear engaged:
Brændstoftemperaturføler: 38.7 °C
A/C pressure sensor: 7.2 bar
Konfiguration: Korrekt
Motor kølevæske temperatur føler: 62.6 °C
Additive adding system fault: Addition of additive not possible
Køleventilatorhastighed: 0.0 %
Cooling fan reference speed: 0.0 %
Batteri spænding: 12.45 V
EGR valve position repeat: 0.0 %
Camshaft and crankshaft synchronization: Nej
Fuel flow regulator: 14.5 %
Diesel output delivered by the pump reference value: 9694.1 mm³/s
Air flow volume: 0.0 kg/h
Motor status: Tænding til
EGR valve open cycle ratio: 0.0 %
Pre-post heating relay: Inaktiv
Motor Hastighed: 0.0 Omdr.
Brændstoftrykføler: 0.0 bar
Accelerator pedal position sensor: 0.0 %
Injected fuel quantity: 21.6 mg/impulse
Luft masse måler: 0.0 mg/impulse
Fuel njection advance (pre): 0.7 °
Fuel injection advance (main): 0.7 °
Injector control error status: No fault
Target turbo pressure: 1.035 bar
Reference fuel pressure: 274.5 bar
Turbo pressure duty cycle: 68.2 %
Bypass throttle solenoid valve open cycle ratio: 0.0 %
EGR throttle electrovalve open cycle ratio: 0.0 %
Catalytic converter downstream temperature: 105.9 °C
Exhaust gas differential pressure: 0.0 mbar
Intake air temperature sensor: 48 °C
Total additive quantity: 18.4 %
Average distance between the last 5 regenerations: 231.1 km
Diesel Particulate filter (DPF) distance since last regeneration: 410.9 km
Air flow reference for EGR: 638.6 mg/impulse
Bypass flap position repeat (if present): 1.2 %
EGR throttle position: 1.2 %
Immobilizer
Locking of the ECU: Ulåst
Statspærrestatus: After-sales status
Problem detected when transmitting the unlock code: No problem
Udgangs test
Controls
Cooling fan high speed
Cooling fan low speed
Additional heating relay
EGR-ventil
EGR throttle
Turbocharger control solenoid valve
Fuel flow regulator
Pre-post heating relay control
Additive pump
Bypass throttle solenoid valve
Muligheder
Controls
Diesel particulate filter static regeneration
Diesel particulate filter dynamic regeneration
Diesel particulate filter replacement
EGR valve change
EGR exchanger replacement
Initialization of the additive level when filling or replacing the additive reservoir
Programming of the additive system if replacing parts (additive reservoir, pump or pipes)
Injectors replacement